Event Code Tables
367
UPM Card Events (500 through 599)
Event Code: 500
Message:
UPM card hot-insertion initiated.
Severity:
Informational
Explanation:
Installation of a UPM card was initiated with the director powered on and
operational. The event indicates that operational firmware detected the presence of
the UPM card, but the card is not seated. When the card is seated in the director
chassis and identified by firmware, an event code 501 is generated.
Action:
If event code 501 follows this event and the amber LED on the UPM card
extinguishes, the replacement card is installed and no additional action is required.
If event code 501 does not follow this event, re-seat the UPM card. If event code
501 still does not display, replace the UPM card.
Event Data:
Byte 0 = UPM slot position (00 through 0F).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 501
Message:
UPM card recognized.
Severity:
Informational.
Explanation:
A UPM card is installed and recognized by director operational firmware.
Action:
No action required.
Event Data:
Byte 0 = UPM slot position (00 through 0F).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...