ADU Error Messages
D-8
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Drive (bay)
X
is a replacement
drive
This drive has been replaced.
This message is displayed if a
drive is replaced in a fault
tolerant logical volume.
If the replacement was
intentional, allow the drive to
rebuild.
Drive (bay)
X
is a replacement
drive marked OK
This drive has been replaced
and marked OK by the
firmware, which may occur if a
drive has an intermittent
failure. For example, a drive
has previously failed, then
starts working again when
ADU is run.
Replace the drive.
Drive (bay)
X
is failed.
The indicated physical drive
has failed.
Replace this drive.
Drive (bay)
X
is undergoing
drive recovery
This drive is being rebuilt from
the corresponding mirror or
parity data.
Normal operations should
occur.
Drive (bay)
X
needs replacing.
The 210-MB hard drive has
firmware version 2.30 or 2.31.
Replace the drive.
Drive (bay)
X
upload code not
readable.
An error occurred while ADU
was trying to read the upload
code information from this
drive.
If there were multiple errors,
this drive may need to be
replaced.
Drive (bay)
X
was
inadvertently replaced.
The physical drive was
incorrectly replaced after
another drive failed.
1. Replace the drive that
was incorrectly replaced.
2. Replace the original drive
that failed.
Do not run the server setup
utility and try to reconfigure;
data will be lost.
continued