ADU Error Messages
D-6
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Configuration signature is zero
ADU detected that nonvolatile
RAM (NVRAM) contains a
configuration signature of zero.
Old versions of the server
setup utility could cause this.
Run the latest version of
server setup utility to configure
the controller and NVRAM.
Configuration signature
mismatch
Array accelerator board
configured for a different array
controller board. Configuration
signature on array accelerator
board does not match the one
stored on the array controller
board.
To recognize the array
accelerator board, run ACU.
Controller communication
failure occurred
Controller communication
failure occurred.
ADU was unable to
successfully issue commands
to the controller in this slot.
Controller detected. NVRAM
configuration not present
EISA nonvolatile RAM
(NVRAM) does not contain a
configuration for this controller.
Run the server setup utility to
configure the NVRAM.
Controller firmware needs
upgrading
Controller firmware is below
the latest recommended
version.
Run Options ROMPaq to
upgrade the controller to the
latest firmware revision.
Controller is located in special
“video” slot
Controller is installed in slot for
special video control signals. If
controller is used in this slot,
LED indicators on front panel
may not function properly.
Install the controller into a
different slot, and run the
server setup utility to configure
NVRAM. Then, run ACU to
configure the controller.
Controller is not configured
Controller is not configured. If
controller was previously
configured and you change
drive locations, there may be a
problem with placement of the
drives. ADU examines each
physical drive and looks for
drives that have been moved
to a different drive bay.
Look for messages indicating
which drives have been
moved. If none are displayed
and drive swapping did not
occur, run ACU to configure
the controller and server setup
utility to configure NVRAM.
Do not
run either utility if you
believe drive swapping has
occurred.
continued