ADU Error Messages
HP Servers Troubleshooting Guide
D-5
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Adapter/NVRAM ID mismatch
EISA nonvolatile RAM
(NVRAM) has an ID for a
different controller from the
one physically present in the
slot.
Run the server setup utility.
Array accelerator battery pack
X
not fully charged
Battery is not fully charged.
If 75% of the batteries present
are fully charged, the array
accelerator is fully operational.
If more than 75% of the
batteries are
not
fully charged,
allow 36 hours to recharge
them.
Array accelerator battery pack
X
below reference voltage
(recharging)
Battery pack on the array
accelerator is below the
required voltage levels.
Allow enough time for batteries
to recharge (36 hours). If
batteries have not recharged
after 36 hours, replace the
array accelerator board.
Board in use by expand
operation
Array accelerator memory is in
use by an expand operation.
Operate the system without
the array accelerator board
until the expand operation
completes.
Board not attached
An array controller is
configured for use with array
accelerator board, but one is
not connected.
Connect array accelerator
board to array controller.
Cache has been disabled
because ADG Enabler Dongle
is broken or missing.
The cache has been disabled
because RAID ADG volume is
configured but the ADG
Enabler Dongle is broken or
missing.
Check the ADG Enabler
Dongle. Replace if needed.
Cache has been disabled;
likely caused by a loose pin on
one of the RAM chips.
Cache has been disabled due
to a large number of ECC
errors detected while testing
the cache during POST. Likely
caused by a loose pin on one
of the RAM chips.
Try reseating the cache to the
controller. If that does not
work, replace the cache.
continued