ADU Error Messages
D-2
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message Description
Recommended
Action
Accelerator board not detected
Array controller did not detect
a configured array accelerator
board.
Install an array accelerator
board on an array controller. If
an array accelerator board is
installed, check for proper
seating on the array controller
board.
Accelerator error log
List of the last 32 parity errors
on transfers to or from the
memory on the array
accelerator board. Displays
starting memory address,
transfer count, and operation
(read and write).
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator parity read errors:
X
Number of times that read
memory parity errors were
detected during transfers from
memory on array accelerator
board.
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator parity write errors:
X
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator status: Cache was
automatically configured
during last controller reset
Cache board was replaced
with one of a different size.
Normal operations should
continue.
Accelerator status: Data in the
cache was lost due to some
reason other than the battery
being discharged.
Data in cache was lost, but not
because of the battery being
discharged.
Check to be sure that the array
accelerator is properly seated.
If the error continues, you may
need to replace the array
accelerator.