POST Error Messages
HP Servers Troubleshooting Guide
C-51
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1722-Slot x Drive
Array - Redundant
Controller Pair Not
Operating
Redundantly (followed
by one of the
following:)
•
Incompatible
controller models.
•
Inter-controller
communication
failed; check
other controller.
•
Incompatible
firmware
versions;
upgrade
firmware.
Array accelerator
RAM sizes are
different.
None
Controllers are not
operating redundantly.
The Smart Array 3100ES or
4250ES Controllers are not
operating properly.
•
In a redundant
configuration, both
controllers must be the
same Smart Array model.
If they are, one of the
controllers or the system
board is defective.
•
The adjacent Smart Array
3100ES or 4250ES
Controller may have
failed.
•
Run Options ROMPaq to
upgrade both controllers
to the same firmware
version.
•
Both Smart Array
3100ES or 4250ES
Controllers must have the
64-MB array accelerator
board connected in order
to operate in redundant
mode.
1723-Slot x Drive
Array - To improve
signal integrity,
internal SCSI
connector should be
removed if external
drives are attached to
the same SCSI port
(followed by detailed
instructions).
None
Cabling problem.
With system power off,
remove or replace connector
daughterboard and/or
external cables connected to
the Smart Array Controller
board as instructed.
continued