POST Error Messages
HP Servers Troubleshooting Guide
C-49
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-13: 1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1713-Slot z Drive
Array Controller -
Redundant ROM
Reprogramming
Failure Replace the
controller if this error
persists after
restarting system.
None
Flash ROM is going bad.
Controller detected a
checksum failure but is
unable to reprogram the
backup ROM.
Replace controller when
possible, or try upgrading
firmware using Options
ROMPaq.
1714-Slot z Drive
Array Controller -
Redundant ROM
Checksum Error
Backup ROM has
automatically been
activated. Check
firmware version.
None
Controller flash operation
interrupted by power-
cycle, or flash ROM may
be going bad.
Controller has detected a
ROM checksum error and
automatically switched to the
backup ROM image. Upgrade
controller firmware using
Options ROMPaq if this
backup ROM image is a lower
version than that originally
running.
1720-Slot
X
Drive
Array – S.M.A.R.T.
Hard Drive(s) Detect
Imminent Failure
SCSI: Port
Y
:
SCSI ID
Z
.
None
Hard drive predictive
failure condition detected.
The indicated drive has
reported a SMART predictive
failure condition. It may fail at
some time in the future.
•
If this drive is part of a
non-fault-tolerant
configuration, back up all
data before replacing the
drive and restore all data
afterward.
•
If this drive is part of a
fault-tolerant
configuration, do not
replace this drive unless
all other drives in the
array are online.
continued