POST Error Messages
HP Servers Troubleshooting Guide
C-41
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
Table C-12: 1600 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1611-Power Supply
Fan
X
not present
None
Required fan not
installed.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-Rear CPU Fan
X
failure detected
None
Required fan not
spinning.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-Rear CPU Fan
X
not present
None
Required fan not
installed.
1. Check
fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-Redundant CPU
Fan Failure Detected
None
Fan not spinning.
1. Check fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
1611-Redundant CPU
fan (Fan
X
) failure
detected
2 short
Redundant CPU fan has
failed.
Replace the failed redundant
CPU fan.
1611-Redundant I/O
Fan (Fan
X
) failure
detected
2 short
Redundant I/O fan has
failed.
Replace the failed redundant
I/O fan.
1611-Redundant
system fan failure
(Fan
X
) detected
None
Required fan has failed.
1. Check fans.
2. Reseat fan cable.
3. If this does not solve the
problem, replace the fan.
continued