POST Error Messages
C-2
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: j-appc POST Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:43 AM
WARNING: To avoid potential problems, ALWAYS read the warnings and
cautionary information in your server-specific user documentation before
removing, replacing, reseating, or modifying system components.
Non-Numeric POST Error Messages or Beeps Only
Table C-2: Non-Numeric Error Messages or Beeps Only
Error Code
Audible
Beeps
Probable Source of
Problem
Action
A Correctable
Memory Error
occurred prior to
this power-up
None
A memory module has
experienced an error
which, while recoverable,
has generated a
predictive failure warning.
Run Diagnostics to identify
and replace the appropriate
memory module.
A Critical Error
occurred prior to
this power-up
None A
catastrophic
system
error, which caused the
server to crash, has been
logged.
Run Diagnostics. Replace
failed assembly as indicated.
A processor thermal
event occurred prior
to this power up,
Processor
X
None Processor
X
(1 or 2) has
reached an excessive
temperature and has
stopped operation.
Check the following
information:
•
The processor and
heatsink assembly is
properly installed.
•
Ambient temperature is
within an acceptable
range.
Beeps only
2 long,
2 short
The power has cycled
because the temperature
is too hot. The processor
fan is not installed, or is
not spinning.
Check fans.
continued