Test Error Codes
HP Servers Troubleshooting Guide
B-13
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
6500-6599, SCSI Hard Drive Test Error Codes
The 6500 series of diagnostic error codes identifies failures with SCSI hard drives,
SCSI hard drive controller boards, SCSI hard drive cabling, and system board
functions. If the system uses a drive array controller, refer to “Array Diagnostic
Utility” in Chapter 4 for more information about diagnosing problems with the drive
array.
Table B-12: SCSI Fixed Disk Drive Test Error Codes
Error
Code
Description Recommended
Action
6500-
XX
SCSI Disk ID drive types
test failed
6502-
XX
SCSI Disk Unconditional
Format test failed
6505-
XX
SCSI Disk Read test failed
6506-
XX
SCSI Disk SA/Media test
failed
The following steps apply to error codes 6500-
XX
through 6528-
XX
:
1. Run the server setup utility and check the drive
type.
2. Replace the SCSI disk drive signal and power
cables and retest.
3. Replace the SCSI controller and retest.
4. Replace the SCSI disk drive and retest.
5. Replace the system board and retest.
6509-
XX
SCSI Disk Erase tape test
failed
6523-
XX
SCSI Disk Random Read
test failed
6528-
XX
Media load/unload test
failed