Test Error Codes
B-8
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
Table B-6: Graphics Controller Unit Test Error Codes
continued
Error Code
Description
Recommended Action
514-
XX
Graphics white screen test
failed
516-
XX
Graphics noise pattern
test failed
600-699, Diskette Drive Test Error Codes
The 600 series of diagnostic error codes identifies failures with diskette, diskette
drive, or system board functions. Corrective action may require replacement of the
diskette, the diskette drive, or the system board assembly.
Table B-7: Diskette Drive Test Error Codes
Error Code
Description
Recommended Action
600-
XX
Diskette ID drive types test
failed
601-
XX
Diskette format failed
602-
XX
Diskette read test failed
603-
XX
Diskette
write/read/compute test
failed
604-
XX
Diskette random seek test
failed
605-
XX
Diskette ID media failed
606-
XX
Diskette speed test failed
607-
XX
Diskette wrap test failed
608-
XX
Diskette write protect test
failed
The following steps apply to error codes 600-
XX
through 610-
XX
:
1. Replace the diskette and retest.
2. Check the diskette power and signal cables and
retest.
3. Replace the diskette power and signal cables
and retest.
4. Replace the diskette drive and retest.
5. Replace the system board and retest.
continued