Test Error Codes
B-2
HP Servers Troubleshooting Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: i-appb Test Error Codes.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:42 AM
100-199, Primary Processor Test Error Codes
The 100 series of diagnostic error codes identifies failures with processor and system
board functions. Corrective action may require replacing system boards or processor
assemblies.
Table B-2: Primary Processor Test Error Codes
Error Code
Description
Recommended Action
101-
XX
CPU test failed
Replace the processor and retest.
103-
XX
DMA page registers test
failed
104-
XX
Interrupt controller master
test failed
105-
XX
Port 61 error occurred
106-
XX
Keyboard
controller
self-test failed
For error codes 103-
XX
through 106-
XX
, replace the
processor and retest.
107-
XX
CMOS RAM test failed
108-
XX
CMOS interrupt test failed
109-
XX
CMOS clock load data test
failed
The following steps apply to error codes 107-
XX
through 109-
XX
.
1. Replace the battery/clock module and retest.
2. Replace the system board and retest.
110-
XX
Programmable timer load
data test failed
111-
XX
Refresh detect test failed
113-
XX
Protected mode test failed
For error codes 110-
XX
through 113-
XX
, replace the
system board and retest.
114-
XX
Speaker test failed
1. Check the speaker connection and retest.
2. Replace the speaker and retest.
3. Replace the system board and retest.
116-
XX
Cache test failed
Replace the system board and retest.
continued