HP Smart Array B140i Скачать руководство пользователя страница 1

HPE Dynamic Smart Array B140i 
RAID Controller 

User Guide 

Abstract 

This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise 

assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy 

levels. 

Part Number:788039-003

b

 

April 2016 

Edition: 4 

Содержание Smart Array B140i

Страница 1: ... person who installs administers and troubleshoots servers and storage systems Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 788039 003b April 2016 Edition 4 ...

Страница 2: ...rd Enterprise shall not be liable for technical or editorial errors or omissions contained herein Microsoft Windows and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Linux is the registered trademark of Linus Torvalds in the U S and other countries Red Hat is a registered trademark of Red Hat Inc in the United Sta...

Страница 3: ...ng hard drives 15 Drive LEDs 15 Recognizing drive failure 15 Effects of a hard drive failure 16 Compromised fault tolerance 16 Recovering from compromised fault tolerance 17 Replacing hard drives 17 Guidelines 17 Data recovery rebuild 18 Time required for a rebuild 18 Abnormal termination of a rebuild 19 Moving hard drives and arrays 20 Adding drives 21 Migrating hard drives to an optional Smart A...

Страница 4: ...latory information 28 Safety and regulatory compliance 28 Belarus Kazakhstan Russia marking 28 Turkey RoHS material content declaration 29 Ukraine RoHS material content declaration 29 Communications interference 29 Acronyms and abbreviations 31 Documentation feedback 33 Index 34 ...

Страница 5: ...ontrollers thus making storage management and deployment easier for IT workers Features The B140i controller has the following features RAID 0 1 10 5 Maximum drives supported 10 Maximum LUNs supported 10 Active Health Support iLO Management support Drive temperature reporting via iLO HPE SSA support UEFI BIOS Smart Carrier support Drive LEDs on page 15 Hot plug and non hot plug configurations SATA...

Страница 6: ...ct a setting and press the Enter key o UEFI Mode default Configures the system to boot to a UEFI compatible operating system NOTE Configure the system to use native UEFI graphic drivers when booting to the UEFI Mode o Legacy BIOS Mode Configures the system to boot to a traditional operating system in Legacy BIOS compatibility mode 3 Press the F10 key to save your selection 4 Reboot the server for ...

Страница 7: ...reater the probability that the array will experience a drive failure during any given period To reduce the risk of data loss that might occur when a drive fails configure all logical drives in an array with a suitable fault tolerance RAID method To configure an array use Intelligent Provisioning on page 24 to enter HPE SSA HPE Smart Storage Administrator on page 23 For more information about usin...

Страница 8: ...ers you must obtain the Hewlett Packard Enterprise custom image for VMware To obtain the custom image see the Hewlett Packard Enterprise website http www hpe com software softwaredepot and select the Virtualization Software Server Virtualization category For more information on supported servers see the HPE ProLiant Gen9 server compatibility matrix for HPE Smart Array controllers on the Hewlett Pa...

Страница 9: ... Linux Enterprise For Ubuntu disc images see the Hewlett Packard Enterprise website http downloads linux hpe com SDR project ubuntu hpdsa Before installing the device drivers observe the following conditions Be sure you have already created a logical volume using the Intelligent Provisioning software Intelligent Provisioning on page 24 or HPE SSA HPE Smart Storage Administrator on page 23 Be sure ...

Страница 10: ... preferred 12 Continue installing the operating system as normal Installing device drivers Red Hat Enterprise Linux 7 To install the device drivers for Red Hat Enterprise Linux 7 1 Enable the controller if necessary 2 Reboot the server 3 Mount the RHEL 7 DVD ISO to iLO virtual media or insert other installation media 4 Press the F11 key to manually select the iLO virtual media or other installatio...

Страница 11: ...ers SUSE Enterprise Linux IMPORTANT Before installing SUSE Linux Enterprise 11 SP3 you must mount the Gen9 kISO boot image and then insert the SUSE Linux Enterprise 11 SP3 DVD when prompted To obtain the kISO image see the SUSE SolidDriver Search website http drivers suse com hp HP ProLiant Gen9 To install the device drivers for SUSE Enterprise Linux 1 Enable the controller if necessary 2 Reboot t...

Страница 12: ...er update image to the USB key dd if hpdsa 1 2 0 185 ubuntu1404 x86_64 img of dev sdc1 To install the device drivers on Ubuntu Server Linux 1 Flash a USB key with a Ubuntu Server Linux disk image using dev sdc1 as the example USB partition gunzip hpdsa 1 2 4 140 ubuntu14 04 2 x86_64 img gz dd if hpdsa 1 2 4 140 ubuntu14 04 2 x86_64 img of dev sdc1 2 Enable the Smart Array controller in the BIOS Pl...

Страница 13: ...page 24 the driver is added automatically during installation No further action is required If you install the operating system without Intelligent Provisioning you must do one of the following Select the driver from the Virtual Install Disk VID This option requires that VID is enabled in System Utilities From the System Utilities screen select System Configuration BIOS Platform Configuration RBSU...

Страница 14: ...Ds connected to the B140i controller 3 For installations that do not use the SATA optical drive to load the Windows installation media when the Where do you want to install Windows screen appears click Load driver and then point to the extracted HPE Dynamic Smart Array B140i RAID controller driver folder ...

Страница 15: ...Solid white Do not remove the drive Removing the drive causes one or more of the logical drives to fail Off Removing the drive does not cause a logical drive to fail 4 Drive status Solid green The drive is a member of one or more logical drives Flashing green The drive is rebuilding or is erasing Flashing amber green The drive is a member of one or more logical drives and predicts the drive will f...

Страница 16: ...re When a hard drive fails all logical drives that are in the same array are affected Each logical drive in an array might be using a different fault tolerance method Therefore each logical drive can be affected differently RAID 0 configurations cannot tolerate drive failure If any physical drive in the array fails all RAID 0 logical drives in the same array also fail RAID 1 configurations can tol...

Страница 17: ... select 1779 from the list of errors Then use the actions on the submenu to re enable the logical drives b Recreate the partitions c Restore all data from backup To minimize the risk of data loss that is caused by compromised fault tolerance make frequent backups of all logical volumes Replacing hard drives If you are replacing a drive in a fault tolerant configuration while the system is powered ...

Страница 18: ...the rebuild to occur If another drive in the array fails while fault tolerance is unavailable during rebuild a fatal system error can occur and all data on the array is then lost In exceptional cases however failure of another drive does not always cause a fatal system error These exceptions include the following Failure after activation of a spare drive Failure of a drive that is not mirrored to ...

Страница 19: ...ctor often eliminates the error 3 Remove and reinsert the replacement drive This action restarts the rebuild process If the rebuild process still terminates abnormally 1 Delete and recreate the logical drive 2 Restore data from backup Case 2 The replacement drive has failed Verify that the replacement drive is of the correct capacity and is a supported model If these factors are not the cause of t...

Страница 20: ...oller If the other controller is connected to one or more arrays of configured logical drives the total number of logical drives on the controller after the drives have been moved must not exceed the number of logical drives that the controller supports This number depends on the controller model and on the controller firmware version If moving the logical volume to a hardware based Smart Array co...

Страница 21: ...ne of the following o Migrate the hard drives Windows o Migrate the hard drives Linux Migrating hard drives to an optional Smart Array controller Windows This section provides instructions to migrate hard drives from an embedded Dynamic Smart Array RAID controller to an optional Smart Array controller in a server with a Microsoft Windows operating system Installing the Smart Array driver Windows T...

Страница 22: ...ive backplane 8 Connect the SAS cable to the controller and hard drive backplane This action replaces the SATA connection 9 Install components and cables removed previously 10 Install the access panel a Power up the server Migrating drives to an optional host bus adapter For information on installing an optional host bus adapter and migrating the drives see the appropriate host bus adapter user gu...

Страница 23: ... in the offline environment such as setting the boot controller and boot volume For more information see Accessing HPE SSA in the offline environment in the HPE Smart Storage Administrator User Guide Accessing HPE SSA in the online environment This method requires an administrator to download the HPE SSA executables and install them You can run HPE SSA online after launching the host operating sys...

Страница 24: ...ing recovery media downloads see the Resources tab on the Hewlett Packard Enterprise website http www hpe com servers intelligentprovisioning For consolidated drive and firmware update packages see the Smart Update Server Firmware and Driver Updates page on the Hewlett Packard Enterprise website http www hpe com info SmartUpdate HPE UEFI System Utilities The HPE UEFI System Utilities is embedded i...

Страница 25: ...p www hpe com support hpesc When prompted for product information enter the server model name Insight Diagnostics Insight Diagnostics is a tool that displays information about the system hardware configuration and performs tests on the system and its components including drives if they are connected to Smart Array controllers This utility is available on the Hewlett Packard Enterprise website http...

Страница 26: ...e occurs following online redemption of the license certificate key How to Use Your Software Technical Support and Update Service Once you are registered you will receive a service contract in the mail containing the Customer Service phone number and your Service Agreement Identifier You will need your SAID when calling for technical support Using your SAID you can also use your SAID to view your ...

Страница 27: ...ic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance i...

Страница 28: ...g Warranties Regulatory information Safety and regulatory compliance For important safety environmental and regulatory information see Safety and Compliance Information for Server Storage Power Networking and Rack Products available at the Hewlett Packard Enterprise website http www hpe com support Safety Compliance EnterpriseProducts Belarus Kazakhstan Russia marking Manufacturer and Local Repres...

Страница 29: ...S material content declaration Ukraine RoHS material content declaration Communications interference Hewlett Packard Enterprise system compliance tests are conducted with Hewlett Packard Enterprise supported peripheral devices and shielded cables such as those received with the system The system meets interference requirements of all countries in which it is sold These requirements provide reasona...

Страница 30: ...e cables according to the instructions provided Ensure that all cable connector screws are firmly tightened Use only Hewlett Packard Enterprise supported peripheral devices Before system operation ensure that all panels and cover plates are in place and secure ...

Страница 31: ...elf Repair FBWC flash backed write cache FCC Federal Communications Commission FIPS Federal Information Processing Standard HPE SSA HPE Smart Storage Administrator iLO Integrated Lights Out IML Integrated Management Log LFF large form factor LUN logical unit number NIST National Institute of Standards and Technology POST Power On Self Test ...

Страница 32: ... Based Setup Utility SATA serial ATA SFF small form factor SMART self monitoring analysis and reporting technology SMH System Management Homepage SPP Service Pack for ProLiant SSD solid state drive UEFI Unified Extensible Firmware Interface ...

Страница 33: ...tion send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hpe com When submitting your feedback include the document title part number edition and publication date located on the front cover of the document For online help content include the product name product version help edition and publication date located on the legal notices page ...

Страница 34: ...mware updating 23 G grounding methods 27 H hard drive failure effects of 16 hard drive replacing 17 hard drives adding 21 hard drives moving 20 HPE Insight Diagnostics 24 HPE Smart Storage Administrator HPE SSA 20 23 I installing device drivers 8 9 13 Intelligent Provisioning 24 J Japanese notice 28 K Keeping the controller current 25 L logical drive capacity extension 21 M Manually injecting the ...

Отзывы: