Diagnostic tools 76
Action
Key
Select items
Enter
Save selections
F10
Access Help for a highlighted configuration
option*
F1
*Scan the QR code on the screen to access online help for the UEFI System Utilities and UEFI Shell.
Default configuration settings are applied to the server at one of the following times:
•
Upon the first system power-up
•
After defaults have been restored
Default configuration settings are sufficient for typical server operations; however, you can modify
configuration settings as needed. The system prompts you for access to the System Utilities each time
the system is powered up.
Embedded Diagnostics option
The system BIOS in all ProLiant Gen9 servers includes an Embedded Diagnostics option in the ROM.
The Embedded Diagnostics option can run comprehensive diagnostics of the server hardware,
including processors, memory, drives, and other server components.
For more information on the Embedded Diagnostics option, see the
UEFI System Utilities User Guide
for ProLiant Gen9 Servers
on the Hewlett Packard Enterprise website
http://www.hpe.com/info/ProLiantUEFI/docs
Re-entering the server serial number and product ID
After you replace the system board, you must re-enter the graphics server blade serial number and the
product ID.
1.
During the graphics server blade startup sequence, press the
F9
key to access UEFI System
Utilities.
2.
Select the
System Configuration
>
BIOS/Platform Configuration (RBSU)
>
Advanced Options
>
Advanced System ROM Options
>
Serial Number
, and then press the
Enter
key.
3.
Enter the serial number and press the
Enter
key. The following message appears:
The serial number should only be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
F10
key to confirm exiting System Utilities. The graphics server blade automatically
reboots.
HPE Insight Diagnostics
The Insight Diagnostics is a proactive graphics server blade management tool, available in both offline