Item
Description
1
System battery
2
Fan connector
3
Channel 1 DIMM slot
4
Channel 2 DIMM slot
5
Drive 2 SATA port
6
Drive 1 SATA port
7
Communication board connector
8
Drive 2 power connector
9
Ambient temperature sensor connector
10
System maintenance switch
11
Drive 1 power connector
System maintenance switch
Position
Default
Function
S1
Off
Off = iLO 4 security is enabled.
On = iLO 4 security is disabled.
S2
Off
Off = System configuration can be changed.
On = System configuration is locked.
S5
Off
Off = Power-on password is enabled.
On = Power-on password is disabled.
S6
Off
Off = No function
On = ROM reads system configuration as invalid.
S3, S4, S7, S8, S9, S10, S11, and S12 —
Reserved
You can access the redundant ROM by setting S1, S5, and S6 to On.
When the system maintenance S6 switch is set to the On position, the system will erase all system
configuration settings from both CMOS and NVRAM on the next reboot. Clearing CMOS, NVRAM, or both
delete configuration information. Be sure to configure the server properly to prevent data loss.
Drive numbering
• Drive numbering for the server
System maintenance switch
67
Содержание ProLiant TM200
Страница 12: ...12 Customer self repair ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 18: ...18 Illustrated parts catalog ...
Страница 57: ...1 2 2 Secure the screw on the fin base end of the heatsink Removal and replacement procedures 57 ...
Страница 70: ...Fan locations Fan location in the server Fan location in the storage expansion unit 70 Fan locations ...
Страница 72: ...Server fan cabling Ambient temperature sensor cabling 72 Server fan cabling ...