background image

 
How are you going to scale out to petabytes with your current infrastructure?

Big data, largely unstructured such as messages, images, readings from sensors, and GPS signals from cell phones, are growing at an
exponential rate. The HP ProLiant SL4545 G7 Server solves the traditional structured database problems when dealing with big data.
Implementing a scale-out infrastructure will invariably result in challenges of data center capacity, spiraling energy costs, infrastructure
complexity and inefficiencies because today's siloed infrastructure is not optimized for scale-out server workloads driven by big data.
The SL4545 G7 Server is a server purpose-built for big data. A highly efficient converged design that delivers the right combination of
capacity and performance, in the least amount of space and at a lower cost.

SL4545 G7 1x60 Model

 

SL4545 G7 1x60 Model Front View:

SL4545 G7 1x60 Model Rear View:

1.

Hood Cover

1.

Fan LED

2.

LFF 3.5" hard drives (60)

2.

System fans

3.

SFF 2.5" hard drives on node (2)

3.

I/O Module

4.

LFF hard drives (30) connected to storage controller (Port 1i) 4.

Management Module

5.

LFF hard drives (30) connected to storage controller (Port 2i) 5.

SL Advanced Power Manager Distribution Module (SL-
APMD)connector

6.

Hard drive backplane health LED

6.

iLO connector

7.

Storage UID

7.

Serial Port

8.

Hard drive LED display boards

8.

10Gb Ethernet SFP+ port

NOTE:

 Available only when 10G I/O module is ordered. 1G I/O

Module has 2x1Gb Ethernet ports only.

9.

Node ejection button

9.

10Gb Ethernet QSFP port

NOTE:

 Available only when 10G I/O module is ordered. 1G I/O

Module has 2x1Gb Ethernet ports only.

10.

Node USB connectors (2)

10.

2 X 1Gb Ethernet ports

11.

Node video connector (VGA port)

11.

Low profile PCI express slot

NOTE: 

Available only when the optional HP SL454x Storage

Mezzanine to PCIe Enablement Kit is ordered

12.

Node power ON/Standby button and system power LED

12.

Power supplies

13.

Node health LED

13.

Power supply LED

QuickSpecs

HP ProLiant SL4545 Generation7 (G7) Server

Overview

DA - 14407   Worldwide — Version 9 — December 13, 2013

Page  1

Содержание ProLiant SL4545

Страница 1: ...1 Fan LED 2 LFF 3 5 hard drives 60 2 System fans 3 SFF 2 5 hard drives on node 2 3 I O Module 4 LFF hard drives 30 connected to storage controller Port 1i 4 Management Module 5 LFF hard drives 30 connected to storage controller Port 2i 5 SL Advanced Power Manager Distribution Module SL APMD connector 6 Hard drive backplane health LED 6 iLO connector 7 Storage UID 7 Serial Port 8 Hard drive LED dis...

Страница 2: ...rt NOTE Available only when 10G I O module is ordered 1G I O Module has 2x1Gb Ethernet ports only 9 Node USB connectors 2 9 10Gb Ethernet QSFP port NOTE Available only when 10G I O module is ordered 1G I O Module has 2x1Gb Ethernet ports only 10 Node power ON Standby button and system power LED 10 2 X 1Gb Ethernet ports 11 Node health LED 11 Low profile PCI express slot NOTE Available only when th...

Страница 3: ...ports only 9 LFF hard drives connected to Server Node 3 15 9 10Gb Ethernet QSFP port NOTE Available only when 10G I O module is ordered 1G I O Module has 2x1Gb Ethernet ports only 10 Hard drive LED display boards 10 2 X 1Gb Ethernet ports 11 Node video connector VGA port 11 Low profile PCI express slot NOTE Available only when the optional HP SL454x Storage Mezzanine to PCIe Enablement Kit is orde...

Страница 4: ...Ms installed options for 1600 1333MHz NOTE Up to 2 processors supported Mixing different processor models is not supported Cache Memory 8MB 1x8MB Level 3 Cache NOTE For Eight core processors Cache is per socket Chipset AMD SR5690 Chipset Based Reference Design AMD Opteron 4200 Series Processor Family NOTE For more information regarding AMD chipsets please see the following URL http www amd com us ...

Страница 5: ...Storage Mezz to PCIe Option Kit 682632 B21 for adding one of the expansion options including an HP IO accelerator networking options or external storage controller options NOTE Expansion Slot is hosted in the I O Module HP Server ROM HP ROM Read Only Memory is now digitally signed using HP s Corporate Signing Service This signature is verified before the flash process starts reducing accidental pr...

Страница 6: ... external support only Optical Drive Via USB port external support only Hard Drives None ship standard Drive Bays 2 SFF drive bays total for each server node 60 LFF drive bays total in chassis for a 1x60 model 50 LFF drive bays total in chassis for a 2x25 model 45 LFF drive bays total in chassis for a 3x15 model Maximum Internal Storage 1x60 Model 60 LFF Drives per node Hot Plug LFF SAS 240 0TB 60...

Страница 7: ...h any combination of SAS SATA or SATA SSD drives to achieve desired performance Interfaces Dedicated to each server node Network RJ 45 Two 1GbE NIC ports available in both 1GbE and 10GbE I O Module NOTE Only one of either the 1GbE I O Module or 10GbE I O Module can be connected to the node SFP connector One 10GbE SFP connector NOTE 10GbE SFP and 10GbE 40GbIB QSFP are additional networking interfac...

Страница 8: ...ghest power supply efficiency without degrading system performance HP CS power supplies are tested by the Electric Power Research Institute EPRI and certified through the ECOS 80 Plus power supply program HP CS power supply options provide efficiency ratings of up to 94 and are available in two power output options 750W and 1200W allowing the user to right size a power supply for their specific se...

Страница 9: ... ProLiant servers HP iLO functions out of the box without additional software installation and functions regardless of the servers state of operation Basic system board management functions diagnostics and essential Lights Out functionality is ship standard The HP iLO can be accessed from any location via a web browser and works hand in hand with HP Systems Insight Manager Insight Control and Insi...

Страница 10: ...user through the steps of discovery analyses and update providing comprehensive information on available updates criticality and interdependencies This information is also available in reports By providing the option of multiple local or shared repositories which can be easily updated from hp com HP SUM provides the tools to optimize stability and consistency throughout the company While HP SUM an...

Страница 11: ... service agreements Hard drives have either a one year or three year warranty NOTE Server Warranty includes 1 year Parts 1 year Labor 1 year on site support with next business day response Warranty repairs may be accomplished through the use of Customer Self Repair CSR parts These parts fall into two categories 1 Mandatory CSR parts are designed for easy replacement A travel and labor charge will ...

Страница 12: ...ps you instantly adjust to dynamic business demands This advanced infrastructure management software lets you reduce the cost of common data center tasks by up to 40 percent while keeping pace with your changing business The HP Matrix OE includes the automated provisioning optimization and recovery management capabilities for HP CloudSystem Matrix the ideal platform for private cloud and Infrastru...

Страница 13: ... as image loading asset tagging and custom packaging HP products supported through Factory Express include a wide array of servers and storage HP Integrity HP ProLiant HP ProLiant Server Blades HP BladeSystem HP 9000 servers as well as the MSAxxxx VA7xxx EVA XP rackable tape libraries and configurable network switches For more information on Factory Express services for your specific server model ...

Страница 14: ...figuration of HP Insight Control or HP SIM Systems Insight Manager on HP ProLiant ML and DL series servers or HP BladeSystem servers or HP ProLiant SL servers http h20195 www2 hp com v2 GetPDF aspx 4AA0 9972ENW pdf For a Hyperscale Environment Datacenter Care is our most flexible and comprehensive support offering HP works in partnership with our customers to provide end to end tailored support fo...

Страница 15: ...s subject to local availability Warranty Service Coverage For ProLiant servers and storage systems the services cover HP branded hardware options qualified for the server purchased at the same time or afterward internal to the enclosure as well as external monitors up to 22 and tower UPS products these items will be covered at the same service level and for the same coverage period as the server u...

Страница 16: ...P Power Advisor is run to determine the right size power supply for your server configuration The HP Power Advisor is located at www hp com go hppoweradvisor HP Common Slot Platinum Plus Power Supply Kits NOTE The following power supplies offer up to 94 efficiency HP 750W Common Slot Platinum Plus Hot Plug Power Supply Kit 656363 B21 HP 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit 656...

Страница 17: ... be selected per server node The HP ProLiant SL454x 1G FIO Module Kit supports two 2 embedded 1Gb NICs The HP SL454x 10G FIO Input Output Module Kit supports two 2 embedded 1Gb NICs and two 2 embedded 10Gb NICs with an optional InfiniBand upgrade NOTE IB supported with addition of HP IB Enablement Kit NOTE 10 Gb Ethernet on the QSFP port requires the use of the QSFP to SFP QSA adapter 655874 B21 H...

Страница 18: ...2632 B21 Rack Adapter HP 13U FIO Rack Adapter Kit for 3X4 3U Chassis NOTE Densely groups three SL4545 chassis into a 13U tall space Order one per three chassis The 0 66U spacer is not used when selecting this option 681677 B21 HP Insight Software HP Insight Control including 1yr 24x7 Support ProLiant ML DL BL bundle Single Server FIO License C6N36A HP Insight Control Encl FIO 16 Svr E LTU C6N33ABE...

Страница 19: ... are all distinct memory technologies and cannot be mixed within a server The majority of AMD based servers support RDIMM and ULVDIMM NOTE Depending on the memory configuration and processor model the memory speed may run at 1600MHz or 1333MHz Please see the Online Memory Configuration Tool at www hp com go ddr3memory configurator Registered DIMMs RDIMM HP 4GB 1x4GB Single Rank x4 PC3L 10600R DDR3...

Страница 20: ...ve 652757 B21 HP 1TB 6G SAS 7 2K rpm LFF 3 5 inch SC Midline 1yr Warranty Hard Drive 652753 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12244_div 12244_div html Worldwide 6G SATA Hot Plug with SmartDrive SFF 2 5 inch Midline MDL Drives HP 1TB 6G SATA 7 2K rpm SFF 2 5 inch SC Midline 1yr Warranty Hard Drive 6...

Страница 21: ...stream Endurance LFF 3 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691854 B21 HP 100GB 6G SATA Mainstream Endurance LFF 3 5 in SC Enterprise Mainstream 3yr Wty Solid State Drive 691852 B21 NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 14038_div 14038_div html Worldwide HP Networking Gigabit Ethernet Ad...

Страница 22: ...ficiency with support for Intelligent Power Discovery HP 750W Common Slot Platinum Plus Hot Plug Power Supply Kit 656363 B21 HP 1200W Common Slot Platinum Plus Hot Plug Power Supply Kit 656364 B21 HP Common Slot Gold Power Supplies NOTE The following power supplies offer up to 92 efficiency HP 750W Common Slot Gold Hot Plug Power Supply Kit 512327 B21 NOTE Kits contain optional power supply an IEC...

Страница 23: ...vailable in EMEA only C6N28ABE HP Insight Control including 1yr 24x7 Technical Support and Updates Single Server License C6N27A HP Insight Control Server Deployment including 1yr 24x7 Support Electronic License T9082AAE HP Insight Control Server Deployment including 1yr 24x7 Support Single Server License 452151 B21 HP Insight Control Server Provisioning Media Kit BD883A HP Insight Management Media...

Страница 24: ...12_div html HP I O Accelerator Options Second Generation Accelerators HP 365GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673642 B21 HP 785GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers 673644 B21 NOTE Need to order HP SL454x Storage Mezzanine to PCIe Enablement Kit to enable the low profile PCIe slot NOTE These are additional expansion options and only one may be selected p...

Страница 25: ...ontroller HP Smart Array P421 1GB FBWC 6Gb 2 ports Ext SAS Controller 631673 B21 HP Smart Array P421 2GB FBWC 6Gb 2 ports Ext SAS Controller 631674 B21 Optional Upgrades HP 12in Super Capacity Option for Smart Array 668943 B21 HP 1GB P series Smart Array Flash Backed Write Cache 631679 B21 HP 2GB P series Smart Array Flash Backed Write Cache 631681 B21 NOTE Due to cabling requirements the HP 12in ...

Страница 26: ...er Cord A0N33A HP C13 GB 1002 CN 250V 10Amp 1 83m Power Cord AF557A HP C13 KSC 8305 KR 250V 10Amp 1 83m Power Cord AF560A HP C13 CNS 690 TW 110V 13Amp 1 83m Power Cord AF561A HP C13 Nema 5 15P TH PH 250V 10Amp 1 83m Power Cord AF559A HP C13 Nema 5 15P US CA 110V 10Amp 1 83m Power Cord AF556A HP C13 IS 1293 IN 240V 6Amp LV 2 0m Power Cord AF562A HP C13 IRAM 2073 AR 250V 10A 2 5m Power Cord AF558A H...

Страница 27: ...iv html Worldwide R5000 Uninterruptible Power System UPS HP R5KVA 3U IEC309 32A High Voltage INTL Uninterruptible Power System AF461A HP R5KVA 3U L630 High Voltage NA JP Uninterruptible Power System AF460A NOTE Please see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 14109_div 14109_div html Worldwide R7000 Uninterruptible Power System UPS HP R7KVA 4U 50A Hi...

Страница 28: ...Three Phase 27 Outlet NA JP Dual Voltage Basic Power Distribution Unit H5M63A HP 8 6kVA 208 Volt Three Phase 30 Outlet NA JP Dual Voltage Basic Power Distribution Unit H5M64A HP 8 6kVA 208 Volt Three Phase 30 Outlet NA JP Basic Power Distribution Unit H5M62A HP 11kVA 400 Volt Three Phase 30 Outlet INTL Basic Power Distribution Unit H5M72A HP Basic Power Distribution Unit Full Height Version HP 11k...

Страница 29: ...ll Height Version HP 8 3kVA 208 Volt 33 Outlet NA Monitored Power Distribution Unit D9N49A HP 7 3kVA 230 Volt 36 Outlet INTL Monitored Power Distribution Unit D9N50A HP 11kVA 400 Volt Three Phase 33 Outlet INTL Monitored Power Distribution Unit D9N57A HP 14 4kVA 208 Volt Three Phase 24 Outlet NA Monitored Power Distribution Unit D9N58A HP 16 6kVA 400 Volt Three Phase 33 Outlet NA Monitored Power D...

Страница 30: ...lligent Power Distribution Unit AF535A HP 17 3kVA 24A 415V Three Phase 12 Outlet Core NA JP Intelligent Power Distribution Unit AF537A HP 22kVA 32A 400V Three Phase 12 Outlet Core INTL Intelligent Power Distribution Unit AF538A iPDU Kits with Standard Extension Bars HP 4 9kVA 24A Single Phase NA JP Intelligent Modular Power Distribution Kit AF531A HP 8 6kVA 24A Three Phase NA JP Intelligent Modula...

Страница 31: ...nsole Rackmount Keyboard FR Monitor AZ873A HP TFT7600 G2 KVM Console Rackmount Keyboard IT Monitor AZ874A HP TFT7600 G2 KVM Console Rackmount Keyboard ES Monitor AZ875A HP TFT7600 G2 KVM Console Rackmount Keyboard DK Monitor AZ876A HP TFT7600 G2 KVM Console Rackmount Keyboard NO Monitor AZ877A HP TFT7600 G2 KVM Console Rackmount Keyboard SE FI Monitor AZ878A HP TFT7600 G2 KVM Console Rackmount Key...

Страница 32: ...business day SL454x 1 Node Chassis Hardware Support U7J55E HP 3 year Next business day Defective Media Retension SL454x 1 Node Chassis Hardware Support U7J56E HP 3 year Next business day SL454x 1 Node Chassis Proactive Service U7J57E HP 3 year Next business day Defective Media Retension SL454x 1 Node Chassis Proactive Service U7J58E HP 3 year 4 hour 13x5 SL454x 1 Node Chassis Hardware Support U7J5...

Страница 33: ...efective Media Retension SL454X Gen8 Tray 1x Node Hardware Support U7K49E HP 3 year 4 hour 24x7 SL454X Gen8 Tray 1x Node Proactive Service U7K50E HP 3 year 4 hour 24x7 Defective Media Retension SL454X Gen8 Tray 1x Node Proactive Service U7K51E HP 3 year 24 hour 24x7 Call to Repair SL454X Gen8 Tray 1x Node Hardware Support U7K54E HP 3 year 24 hour 24x7 Defective Media Retension SL454X Gen8 Tray 1x ...

Страница 34: ...rocessors It is not required but it is recommended to load the channels similarly if possible DIMM slot capacity populated speed table DIMM Type Registered DIMMS RDIMMs DIMM Rank Single Rank 1R Dual Rank 2R Quad Rank 4R DIMM Capacity 4GB 2GB 8GB 16GB 16GB DIMM Native Speed MHz 1333 1333 1333 1333 1066 Voltage LV Std Std LV Std LV Std Std SLOTS THAT CAN BE POPULATED 12 slot servers 12 12 12 12 4 MA...

Страница 35: ...rder start with A first B second C third etc 12 DIMM SLOTS 6 per CPU CPU1 CPU2 slot population order slot population order Chnl 1 1 A 1 A Chnl 1 2 E 2 E 3 C 3 C Chnl 2 4 B 4 B Chnl 2 5 F 5 F 6 D 6 D NOTE slots 1 and 4 are furthest from the CPU slots 3 and 6 are closest RDIMM maximum configuration 2 CPU model 192GB consisting of twelve 12 16GB Dual Ranked PC3L 10600 RDIMMs QuickSpecs HP ProLiant SL...

Страница 36: ... 16GB DIMM 4 B 16GB DIMM Chnl 2 5 F 16GB DIMM 5 F 16GB DIMM 6 D 16GB DIMM 6 D 16GB DIMM NOTE Capacity references are rounded to the common Gigabyte values 1GB 1024MB 2GB 2048MB 4GB 4096MB 8GB 8192MB 16GB 16384MB DDR3 memory options part number decoder QuickSpecs HP ProLiant SL4545 Generation7 G7 Server Memory DA 14407 Worldwide Version 9 December 13 2013 Page 36 ...

Страница 37: ...t www hp com go ddr3memory configurator Registered DIMMs RDIMM HP 4GB 1x4GB Single Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage Memory Kit 647871 B21 HP 8GB 1x8GB Dual Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage Memory Kit 647877 B21 HP 16GB 1x16GB Dual Rank x4 PC3L 10600R DDR3 1333 Registered CAS 9 Low Voltage Memory Kit 647883 B21 Ultra Low Voltage DIMM ULVDIMM HP 4G...

Страница 38: ...25 Model 1 2 2 x SFF SATA SATA SDD Hot Plug SFF Hard Drive Bays for server node 1 1 2 2 x SFF SATA SATA SDD Hot Plug SFF Hard Drive Bays for server node 2 1 25 25 x LFF SATA SAS SDD Hot Plug Hard Drive Bays for server node 1 1 25 25 x LFF SATA SAS SDD Hot Plug Hard Drive Bays for server node 2 QuickSpecs HP ProLiant SL4545 Generation7 G7 Server Storage DA 14407 Worldwide Version 9 December 13 2013...

Страница 39: ...D Hot Plug Hard Drive Bays for server node 3 Maximum Storage Capacity 1x60 Model Internal 2 SFF Drive Cage 2TB 2 x 1TB SATA SFF Internal 60 LFF Drive Cage 240TB 60 x 4TB SATA LFF Total 242TB Maximum Storage Capacity 2x25 Model Internal 2 SFF Drive Cage 4TB 4 x 1TB SATA SFF Internal 60 LFF Drive Cage 200TB 50 x 4TB SATA LFF Total 204TB Maximum Storage Capacity 3x15 Model Internal 2 SFF Drive Cage 6...

Страница 40: ...20 VAC 1200 W at 200 to 240 VAC Maximum Peak Power For 1200 W Power Supply 800 W at 100 VAC 900 W at 120 VAC 1200 W at 200 to 240 VAC For 750 W Power Supply 750 W at 100 to 120 VAC 750 W at 200 to 240 VAC Power Specifications To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL www hp com go proliant energy efficient or www hp com go...

Страница 41: ... declared average bystander position A Weighted sound pressure levels LpAm when the product is operating in a 23 C ambient environment Noise emissions were measured in accordance with ISO 7779 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle L WAd 7 13 B L pAm 57 39dBA Operating L WAd 7 13 B L pAm 57 43dBA Emissions Classification EMC FCC Rating Class A Normative Standards CISPR 22 E...

Страница 42: ...TX Full Duplex 200 Mb s per port 400 Mb s Combined 1000Base TX Half and Full Duplex 1000Mb s per port 2000 Mb s Combined Connector RJ 45 Cable Support 10Base T Categories 3 4 or 5 UTP up to 328 ft 100 m 10 100 1000Base TX Category 5 UTP up to 328 ft 100 m HP Ethernet 10Gb 2P 544i Adapter Data Transfer Method Compliant to x8 PCIe Gen2 Specification Network Transfer Rate X4 IB 10 Gb s SDR 20 Gb s DD...

Страница 43: ... to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at htt...

Страница 44: ...QuickSpecs HP ProLiant SL4545 Generation7 G7 Server Technical Specifications DA 14407 Worldwide Version 9 December 13 2013 Page 44 ...