Connectors, switches, and LEDs 74
Item
Designator Description
26
J40
VGA port
Serial port connection is compatible with the DIGI CM RJ-45 and Sun/Cisco RJ-45. Straight Cat 5e cable
can be used for this interface.
For connecting to Cyclades connection, use ADB2239. For connecting to DB9M connection, use rolled
cat5e and digi76000702 or manually wire with Digikey P/N 046-0000-ND.
Table 1
Pin out information
Item
SL390s serial port
DIGI CM RJ-45 Sun RJ-45
Cisco RJ-45
Cyclades RJ-45
1
RTS
CTS
CTS
RTS
RTS
2
DTR
DSR
DSR
DTR
DTR
3
TXD
RXD
RXD
TXD
TXD
4
GND
GND
GND
GND
GND
5
DCD
DCD
DCD
DCD
CTS
6
RXD
TXD
TXD
RXD
RXD
7
DSR
DTR
DTR
DSR
DCD
8
CTS
RTS
RTS
CTS
DSR
Jumpers and switches
Chassis ID (J29) jumper
Table 2
System configuration jumper settings
Jumper
Status
J29
1-2, default setting, 2-3 clear CMOS
All switches are off as default.
Table 3
System maintenance switch
Position
Description
Definition
1
iLO Security Override
OFF = normal
ON = security disabled
2
Configuration Lock
OFF = normal
ON = configuration locked
3
Reserved
—
4
Reserved
—
5
Password Disable
OFF = normal
ON = power-on password disabled
Содержание ProLiant SL390s G7 2U
Страница 12: ...Customer Self Repair 12 ...
Страница 13: ...Customer Self Repair 13 ...
Страница 14: ...Customer Self Repair 14 ...
Страница 15: ...Customer Self Repair 15 ...
Страница 26: ...Illustrated parts catalog 26 ...
Страница 32: ...Removal and replacement procedures 32 Figure 1 Removing the left server Figure 2 Removing the right server ...