Component identification 98
NVMe SSD components
Item Component
Status
Definition
1
Release lever
—
Ejects the NVMe drive carrier from the cage.
2
Activity ring LED Rotating green
Off
Drive activity
No drive activity
3
Do Not Remove
LED
Solid white
Flashing white
Off
Drive is powered on, and configured in system.
Do not remove the drive.
Ejection request pending. Do not remove the drive.
Drive removed from the PCIe bus, and can be ejected.
4
Power LED
Solid green
Flashing green
Off
Drive is powered on, and configured in system.
Do not remove the drive.
Ejection request pending. Do not remove the drive.
Drive removed from the PCIe bus, and can be ejected.
5
Power button
—
Momentary press to request drive removal from PCIe bus
and ejection. Drive removal request can be denied by
operating system.
6
Do Not Remove
button
—
Releases the release lever for removal and insertion.
Upon NVMe SSD insertion, an LED initiation sequence will be visible - lighting each LED in the carrier in sequence from left to
right. The sequence will cycle until the drive is recognized by the system. When the SSD is recognized by the system - the Do Not
Remove LED will be solid white and the Power LED will be solid green.
Hot-plug fans
The server supports redundant hot-plug fans to provide proper airflow to the system when a primary fan
fails.
CAUTION:
To avoid damage to server components, a fan or fan blank must always be
installed in fan bay 1.
CAUTION:
To avoid damage to the equipment, do not operate the server for extended
periods of time if the server does not have the optimal number of fans installed. Although the
server might boot, Hewlett Packard Enterprise does not recommend operating the server
without the required fans installed and operating.
Содержание ProLiant ML350 Gen9
Страница 5: ...Contents 5 Index 123 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 18: ...Illustrated parts catalog 18 ...
Страница 64: ...Removal and replacement procedures 64 LFF configuration SFF configuration ...
Страница 91: ...Component identification 91 o Rack orientation 24 LFF drives o Tower orientation ...
Страница 104: ...Cabling 104 Storage controller installed in slot 1 to 4 Storage controller installed in slot 6 to 9 ...
Страница 105: ...Cabling 105 HPE Smart Storage Battery cabling Power supply backplane cabling GPU power cabling ...
Страница 109: ...Cabling 109 Embedded SATA cabling LFF configuration SFF configuration ...
Страница 112: ...Cabling 112 o SFF configuration o LFF configuration SAS Expander cabling One SAS Expander ...
Страница 113: ...Cabling 113 o LFF configuration o SFF configuration ...
Страница 114: ...Cabling 114 Two SAS Expanders Express bay cabling Express bay bridge card installed in PCIe slot 3 ...