Specifications
Server Specifications
Table F-1: ProLiant ML310 Server Specifications
Dimensions
Height
42.0 cm (16.5 in)
Depth
48.5 cm (19.1 in)
Width
19.1 cm (7.5 in)
Approximate weight
18.18 kg (40 lb), depending on options
Input specifications
(per power supply)
U.S. International
Rated input voltage
100 VAC to 120 VAC
200 VAC to 240 VAC
Rated input frequency
50 Hz to 60 Hz
50 Hz to 60 Hz
Rated input current
6 A
3 A
Input power (Btu/hr)
1,560 Btu/hr
1,560 Btu/hr
Output specifications (per power supply)
Rated steady-state
power
300 W
Maximum peak power
400 W
Temperature range (see Note)
Operating 50
°
F to 95
°
F 10
°
C to 35
°
C
Shipping -40
°
F to 158
°
F -40
°
C to 70
°
C
Maximum wet bulb
temperature
82.4
°
F 28
°
C
Relative humidity (noncondensing)
Operating
10% to 90%
10% to 90%
Nonoperating
5% to 95%
5% to 95%
Note: All temperature ratings shown are for sea level. There is an altitude
derating of 1°C per 300 m to 3,000 m (1.8°F per 1,000 ft to 10,000 ft).
F-2
HP ProLiant ML310 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Ted Weiman File Name: m-appf.doc
Codename: Son of Beast Part Number: 274431-002 Last Saved On: 11/22/02 2:11 PM