Removal and Replacement Procedures
HP ProLiant ML310 Server Maintenance and Service Guide
2-41
IMPORTANT:
Positive (+) polarity must be positioned up.
5. Slide the replacement battery into the proper position with the positive (+) side up.
6. Replace the server access panel and connect cables to the server.
7. Run RBSU to reconfigure the server by pressing the
F9
key when prompted during server
startup. Refer to the
ROM-Based Setup Utility User Guide
for more information on
RBSU.
Re-entering the Server Serial Number
After replacing the system board or clearing the NVRAM, the server serial number must be
re-entered.
1. During the server startup sequence, press the
F9
key to access RBSU.
2. Select
the
System Options
menu.
3. Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the
Enter
key to clear the warning.
4. Enter the serial number and press the
Enter
key.
5. Press
the
Escape
key to close the menu.
6. Press
the
Escape
key to exit RBSU.
7. Press
the
F10
key to confirm exiting RBSU. The server will automatically reboot.