Removal and replacement procedures 23
•
Remove the system air baffle (on page
•
If installed, remove the PCI air baffle (on page
•
Remove the fans (on page
Remove the tower bezel
1.
Using the key provided with the server, unlock the bezel with a clockwise turn.
2.
Remove the tower bezel.
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of
critical server data and programs.
IMPORTANT:
When the server is in standby mode, auxiliary power is still being provided to
the system.
To power down the server, use one of the following methods:
•
Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters
standby mode.
•
Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter
standby mode.
This method forces the server to enter standby mode without properly exiting applications and the
OS. If an application stops responding, you can use this method to force a shutdown.
•
Use a virtual power button selection through iLO 4.
This method initiates a controlled remote shutdown of applications and the OS before the server
enters standby mode.
Before proceeding, verify the server is in standby mode by observing that the system power LED is
amber.
Содержание ProLiant ML150 Gen9
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 29: ...Removal and replacement procedures 29 o Box 2 o Box 1 ...
Страница 78: ...Cabling 78 Cabling Front panel cabling Item Description 1 Front I O cable 2 USB 3 0 connector cable ...
Страница 86: ...Cabling 86 Cache module backup power cabling HPE Smart Storage Battery cabling ...