![HP ProLiant ML110 G6 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/hp/proliant-ml110-g6/proliant-ml110-g6_maintenance-and-service-manual_164835056.webp)
Removal and replacement procedures 56
2.
Install the SAS cache battery.
a.
Mount the SAS cache battery on the chassis indentation located below the HDD cage (
1
).
b.
Connect the BBWC cable to the SAS controller board (
2
).
3.
Proceed to page 40 for instructions on how to install a SAS hard drive.
Flash-backed write cache procedures
Two types of procedures are provided for the FBWC option:
•
Removal and replacement of failed components:
•
Removing the cache module
•
Removing the capacitor pack
•
Recovery of cached data from a failed server
CAUTION:
Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.
Flash-backed write cache module
To remove the component:
CAUTION:
Do not use this controller with cache modules designed for other controller
models, because the controller can malfunction and you can lose data. Also, do not transfer
this cache module to a different controller module, because you can lose data.
1.
Back up all data.
2.
Close all applications.
3.
Power down the server.
Содержание ProLiant ML110 G6
Страница 12: ...Customer Self Repair 12 ...
Страница 13: ...Customer Self Repair 13 ...
Страница 14: ...Customer Self Repair 14 ...
Страница 15: ...Customer Self Repair 15 ...
Страница 16: ...Illustrated parts catalog 16 Illustrated parts catalog Mechanical components ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 20: ...Illustrated parts catalog 20 System components ...
Страница 25: ...Illustrated parts catalog 25 ...
Страница 90: ...Diagnostics tools 90 ...