1.

DVD-ROM Drive

1.

Rear System fan

2.

Power LED

2.

PCI Slot Cover Retainer

3.

Drive Activity LED

3.

PCI Slot Covers

4.

Front Bezel

4.

HP ProLiant 100 G5 Lights-Out 100c Management Card
Port (Optional)

5.

SAS Cable (SAS model only)

5.

LAN Port (RJ-45)

6.

Hard Drive Controller Card (Optional)

6.

Rear USB 2.0 Ports

7.

System Board

7.

Serial Port

8.

HP ProLiant 100 G5 Lights-Out 100c Management Card
Port (Optional)

8.

VGA Port

9.

PS/2 Keyboard Port

9.

System Fan

10. PS/2 Mouse Port

10.

365W Power Supply

11. Power Supply Outlet

 

 

12. Power Supply Unit (PSU) Fan

What's New

What's New

What's New

What's New

Support for Quad-Core and Dual-Core Intel® Xeon® processors 3300 and 3100 sequence
Support for SAS Enterprise (ENT) Non-Hot Plug Hard Drives

QuickSpecs

HP ProLiant ML110 Generation 5 (G5)

HP ProLiant ML110 Generation 5 (G5)

HP ProLiant ML110 Generation 5 (G5)

HP ProLiant ML110 Generation 5 (G5)

Overview

DA - 12867   North America — Version 14 — September 15, 2008

Page 1

Содержание ProLiant ML110 G5

Страница 1: ...Port 8 HP ProLiant 100 G5 Lights Out 100c Management Card Port Optional 8 VGA Port 9 PS 2 Keyboard Port 9 System Fan 10 PS 2 Mouse Port 10 365W Power Supply 11 Power Supply Outlet 12 Power Supply Unit PSU Fan What s New What s New What s New What s New Support for Quad Core and Dual Core Intel Xeon processors 3300 and 3100 sequence Support for SAS Enterprise ENT Non Hot Plug Hard Drives QuickSpecs...

Страница 2: ... 100 IPMI 2 0 reporting Optional HP ProLiant 100 G5 Lights Out 100c Remote Management Card Standard HP ProLiant ML110 G5 Easy Set up CD Form Factor Form Factor Form Factor Form Factor Micro ATX tower 4U Warranty Warranty Warranty Warranty This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners Hardware diagnostic s...

Страница 3: ...e details Dual Core Dual Core Dual Core Dual Core Dual Core Intel Xeon processor E3120 3 16 GHz 65W 1333MHz FSB 6M NOTE NOTE NOTE NOTE Available through Configure To Order only See Factory Integration Models section for more details Dual Core Intel Xeon processor E3110 3 00 GHz 65W 1333MHz FSB 6M NOTE NOTE NOTE NOTE Available through Configure To Order only See Factory Integration Models section f...

Страница 4: ...ogy Technology Technology Technology Bus Width Bus Width Bus Width Bus Width Connector Connector Connector Connector Width Width Width Width Bus Number Bus Number Bus Number Bus Number Device Device Device Device Number Number Number Number Form Factor Form Factor Form Factor Form Factor Notes Notes Notes Notes 1 PCI 32 bit N A 0 30 Full height slot 133MHz 3 3V 2 PCIe X1 X8 0 28 Full height slot 3...

Страница 5: ...Plug SATA Non Hot Plug SATA 3 0TB 4 x 750GB Not Hot plug SAS Not Hot plug SAS Not Hot plug SAS Not Hot plug SAS 1 8TB 4 x 450GB Interfaces Interfaces Interfaces Interfaces Parallel 0 Serial 1 Pointing Device Mouse PS2 1 Graphics 1 Keyboard PS2 1 USB 2 0 Ports 8 total 4 rear 2 front panel 2 internal one for USB Tape connectivity NOTE NOTE NOTE NOTE Internal USB ports are optimal for the attachment ...

Страница 6: ...ding a simple way to deploy reliable and consistent server configurations The HP ProLiant 100 Series Easy Set up CD ship standard with the ML110 G5 It offers essential single server deployment tools for HP ProLiant 100 series servers that simplify HP entry server setup providing a repeatable way to deploy reliable and consistent single server configurations The HP ProLiant Easy Set up CDs assist w...

Страница 7: ... Power Cords Server Power Cords Server Power Cords 6 lowline NEMA power cord Power Supply Power Supply Power Supply Power Supply 365 Watts System Fans System Fans System Fans System Fans 1 non redundant system fan shipped standard 1 non redundant CPU heatsink fan shipped standard OS Support OS Support OS Support OS Support Microsoft Windows Server 2003 Web edition Microsoft Windows Server 2003 Win...

Страница 8: ... 22 and smaller external monitors and tower UPS options up to 3kVA These items will be covered at the same service level and for the same coverage period as the server Coverage of UPS Battery is not included and standard warranty terms conditions apply For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within the same rack To fully ca...

Страница 9: ...emory Memory Memory 512 MB PC2 6400 ECC DDR2 800MHz 1 x 512 MB Storage Controller Storage Controller Storage Controller Storage Controller HP Embedded 6 Port SATA Controller with Embedded RAID 4 ports for HDD Hard Drive Hard Drive Hard Drive Hard Drive 160GB SATA HDD Internal Storage Internal Storage Internal Storage Internal Storage Non Hot Plug SATA Maximum 3 0TB 4 x 750GB SATA Optical Drive Opt...

Страница 10: ...roller Storage Controller Storage Controller Storage Controller HP SC40Ge Host Bus Adapter with RAID 0 1 support Hard Drive Hard Drive Hard Drive Hard Drive 72GB SAS HDD Internal Storage Internal Storage Internal Storage Internal Storage Non Hot Plug SAS Maximum 1 8TB 4 x 450GB SAS Optical Drive Optical Drive Optical Drive Optical Drive 16x SATA DVD ROM Form Factor Form Factor Form Factor Form Fac...

Страница 11: ...orage Controller Storage Controller Storage Controller Storage Controller HP Embedded 6 Port SATA Controller with embedded RAID 4 ports for HDD Hard Drive Hard Drive Hard Drive Hard Drive 1 160GB SATA 7 2K 3 5 Internal Storage Internal Storage Internal Storage Internal Storage Maximum 3 0TB 4 x 750GB SATA Optical Drive Optical Drive Optical Drive Optical Drive 16x DVD RW Drive Form Factor Form Fac...

Страница 12: ...troller Storage Controller HP Embedded 6 Port SATA Controller with embedded RAID 4 ports for HDD Hard Drive Hard Drive Hard Drive Hard Drive 1 160GB SATA 7 2K 3 5 Internal Storage Internal Storage Internal Storage Internal Storage Maximum 3 0TB 4 x 750GB SATA Optical Drive Optical Drive Optical Drive Optical Drive DVD ROM Drive Form Factor Form Factor Form Factor Form Factor Micro ATX Tower QuickS...

Страница 13: ...Guide CTO RAID set up is not available HP ProLiant ML100 Series Server User Guide http h20000 www2 hp com bc docs support SupportManual c00260539 c00260539 pdf Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from ...

Страница 14: ...ine MDL Drives SATA Non Hot Plug Midline MDL Drives HP 750GB 3G SATA 7 2K NHP 3 5 MDL HDD 462595 B21 HP 500GB 3G SATA 7 2K NHP 3 5 MDL HDD 458941 B21 HP 250GB 3G SATA 7 2K NHP 3 5 MDL HDD 458939 B21 SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives HP 160GB 3G SATA 7 2K NHP 3 5 ETY HDD 458947 B21 SAS Enterpri...

Страница 15: ...dard Edition Pre install Microsoft Windows 2003 SBS Standard Edition MS W2003 SBS R2 Std 1XX FIO Eng SW 432564 001 MS W2003 SBS R2 Prm 1XX FIO Eng SW 432566 001 Step 4 Choose Additional Options for Factory Integration Step 4 Choose Additional Options for Factory Integration Step 4 Choose Additional Options for Factory Integration Step 4 Choose Additional Options for Factory Integration NOTE NOTE N...

Страница 16: ...ug Drives NOTE NOTE NOTE NOTE The following previous generation of 1 5G SATA Hot Plug hard drives are supported These drives can be purchased as an option however are no longer configurable HP 250GB 1 5G SATA 7 2K NHP 3 5 HDD 411276 B21 HP 160GB 1 5G SATA 7 2K NHP 3 5 HDD 411275 B21 NOTE NOTE NOTE NOTE SATA drives have a 1 year warranty Please see the QuickSpecs for Technical Specifications and ad...

Страница 17: ...www1 hp com products quickspecs 12460_na 12460_na html Smart Array E200 Controller 411508 B21 HP SAS SATA 4 Port Cable NOTE NOTE NOTE NOTE The purchase of a SAS Storage Controller requires the purchase of HP SAS SATA 4 Port Cable P N 457692 B21 457692 B21 NOTE NOTE NOTE NOTE SAS Storage Controllers supports both SATA and SAS drives NOTE NOTE NOTE NOTE On SATA models with embedded RAID setup instru...

Страница 18: ...EH978A HP D2D Backup System HP D2D Backup System HP D2D Backup System HP D2D Backup System RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup HP StorageWorks RDX160 Internal Removable Disk Backup System NOTE NOTE NOTE NOTE 160GB of Disk Storage AJ765A HP StorageWorks RDX320 Internal Removable Disk Backup System NOTE NOTE NOTE NOTE 320GB of Disk ...

Страница 19: ...e QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12192_na 12192_na html HP PWR CRD 1 83m 10A C13 UL DOM AF556A USB Options USB Options USB Options USB Options HP 1GB USB 2 0 Floppy Drive Key 442085 B21 HP 256MB USB 2 0 Floppy Drive Key 442084 B21 1 44MB External USB Floppy Drive ALL DC141B HP USB 2 Button Optical Mouse ALL DC172B HP U...

Страница 20: ...e 3 Years Electronic U4435E Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service 6 Hour Call to Repair On Site Service 7 Day x 24 Hour Coverage 3 Years Electronic U4436E Hardware Installation Hardware Installation Hardware Instal...

Страница 21: ...DRAM DIMM Memory kits NOTE NOTE NOTE NOTE The below chart does not represent all possible memory configurations NOTE NOTE NOTE NOTE For best performance it is recommended that customer installs memory in identical pairs Slots 1 and 3 are interleaving pair Slots 2 and 4 are interleaving pair Memory Memory Memory Memory Slot Slot Slot Slot 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 Standard Standard Standard S...

Страница 22: ...t SATA controller with Embedded RAID on Motherboard SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives SATA Non Hot Plug Entry ETY Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 160GB 3G 7 2...

Страница 23: ...OTE NOTE NOTE NOTE For an up to date listing of the latest O S Support details for each of the Tape Drives listed below please see the following http h18000 www1 hp com products quickspecs north_america 10233 html Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Controller HBA Controller HBA Controller HBA Controller HBA Option...

Страница 24: ...e Disk Backup Removable Disk Backup System System System System RDX160 RDX320 2 USB 2 0 Port N A HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D Backup Systems Backup Systems Backup Systems Backup Systems D2D120 D2D130 External Embedded Network Controller N A QuickSpecs HP ProLiant ML110 Generation 5 G5 HP ProLiant ML110 Generation 5 G5 HP ProLiant ML110 Generation ...

Страница 25: ...240 240 Max Rated Output Wattage Rating 365 365 365 365 365 Nominal Input Current A rms 6 N A 3 N A N A Max Rated Input Wattage Rating Watts N A N A N A N A N A Max Rated VA Volt Amp 600 N A N A N A N A Efficiency 65 65 65 65 65 Power Factor N A N A N A N A N A Leakage Current mA N A 0 45mA N A N A N A Maximum Inrush Current A peak N A No component was damaged and input fuse shall not blow N A No ...

Страница 26: ...with all power supplies loaded A 150A 240Vac Power cord requirements Nema 5 15P to IEC320 C13 IEC320 C13 to IEC320 C14 Power shown is for a fully configured system consisting of 1 CPU 4 double sided DIMMs 4 HDDs 1 DVD ROM 4 PCI cards and 1 power supply Power Cords Power Cords Power Cords Power Cords 13 Cord Sets Power Cord Part Number Power Cord Part Number Power Cord Part Number Power Cord Part N...

Страница 27: ...r 365 W at 100 VAC 365 W at 200 VAC Maximum Peak Power 385 W at 100 VAC 385 W at 200 VAC System Inlet Temperature System Inlet Temperature System Inlet Temperature System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate ...

Страница 28: ...L L WAd 5 2 Bels L L L L pAm 34 dBA Operating L L L L WAd 5 7 Bels L L L L pAm 40 dBA Emissions Classification Emissions Classification Emissions Classification Emissions Classification EMC EMC EMC EMC FCC Rating FCC Rating FCC Rating FCC Rating Class B Normative Standards Normative Standards Normative Standards Normative Standards CISPR 22 EN55022 EN55024 FCC CFR 47 Pt 15 ICES 003 CNS13438 GB9254...

Страница 29: ...ure Operating Temperature Operating Temperature Operating Temperature 41 to 131 F 5 to 55 C NHP 72GB 3G SAS 15K NHP 72GB 3G SAS 15K NHP 72GB 3G SAS 15K NHP 72GB 3G SAS 15K 3 5 HDD 3 5 HDD 3 5 HDD 3 5 HDD 432095 B21 72GB 15K 72GB 15K 72GB 15K 72GB 15K Capacity Capacity Capacity Capacity 73 407 856 856 Height Height Height Height 1 0 in 25 4mm Width Width Width Width 4 0 in 101 6 mm Interface Interf...

Страница 30: ...us Adapter Host Bus Adapter Host Bus Adapter Host Bus Adapter SAS SATA HP Model SATA Protocol SATA Protocol SATA Protocol SATA Protocol SATA 1 5Gb s SATA Ports SATA Ports SATA Ports SATA Ports 4 internal Port transfer rate Port transfer rate Port transfer rate Port transfer rate 1 5 Gb s total Maximum Capacity Maximum Capacity Maximum Capacity Maximum Capacity up to 3 0TB 4 x 750GB Non Hot Plug SA...

Страница 31: ...s Adapter with RAID Bus Adapter with RAID Bus Adapter with RAID Bus Adapter with RAID RAID Support RAID Support RAID Support RAID Support RAID 1 Mirroring RAID 0 Striping Logical Drives Supported Logical Drives Supported Logical Drives Supported Logical Drives Supported Up to 2 Logical Volumes Up to 10 drives total in all RAID volumes Up to 2 Drives per RAID 1 Up to 8 Drives per RAID 0 Maximum Cap...

Страница 32: ...ams in many geographic areas For trade in information please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for u...