Hardware options installation 56
Processor installation cautions
The server supports single-processor and dual-processor operations.
CAUTION:
To avoid damage to the processor and system board, only authorized personnel
should attempt to replace or install the processor in this server.
CAUTION:
To prevent possible server overheating, always populate each processor socket
with a processor socket cover and a processor blank, or a processor and a heatsink.
CAUTION:
To prevent possible server malfunction and damage to the equipment,
multiprocessor configurations must contain processors with the same part number.
IMPORTANT:
If installing a processor with a faster speed, update the system ROM before
installing the processor.
IMPORTANT:
Processor socket 1 must be populated at all times or the server does not
function.
For optimum performance, Hewlett Packard Enterprise recommends:
•
Use DIMMs that match the speed of the processor installed in the server. Intel Xeon E5-2600 v4
processors are optimized to work with 2400 MHz DIMMs.
•
In a multiprocessor configuration, balance the total capacity of the DIMMs across the processors.
Installing a processor
To install the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel (on page
5.
Remove the second processor blank.
Содержание ProLiant DL60 Gen9
Страница 14: ...Component identification 14 Fan locations ...
Страница 22: ...Operations 22 o Secondary PCI riser cage o PCI blank ...
Страница 86: ...Cabling 86 FBWC module slot 1 cabling FBWC module slot 2 cabling ...
Страница 87: ...Cabling 87 FBWC module slot 3 cabling Smart Storage battery cabling ...
Страница 117: ...Support and other resources 117 ...
Страница 118: ...Support and other resources 118 ...