Removal and replacement procedures 77
2.
Remove the power input module.
To replace the component, reverse the removal procedure.
Redundant power supply backplane
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
1.
Power down the server (on page
2.
Access the product rear panel (on page
3.
Release the power cord from the hook-and-loop strap.
4.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
5.
Remove all installed power input modules.