Removal and replacement procedures 69
11.
Install the heatsink.
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
12.
Install all components removed from the failed system board.
13.
Install the access panel ("
14.
Install the power supplies ("
15.
Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warning appears:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.
7.
Select
Product ID
. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
8.
Enter the product ID and press the
Enter
key.
9.
Press the
Esc
key to close the menu.
10.
Press the
Esc
key to exit RBSU.
11.
Press the
F10
key to confirm exiting RBSU. The server automatically reboots.
150W PCIe power cable option
Содержание ProLiant DL385p
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 50: ...Removal and replacement procedures 50 o 8 or 16 SFF configuration o 8 LFF configuration ...
Страница 90: ...Cabling 90 Cabling SAS hard drive cabling SFF hard drive cabling SFF cabling with optional drive cage ...
Страница 91: ...Cabling 91 LFF hard drive cabling Optical drive cabling ...
Страница 92: ...Cabling 92 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Страница 99: ...Acronyms and abbreviations 99 UID unit identification USB universal serial bus ...