Component identification 70
Systems Insight Display
LED and color
Internal health
LED color
Status
Processor (amber)
Red
One or more of the following conditions may exist:
•
Processor in socket
X
has failed.
•
Processor
X
is not installed in the socket.
•
Processor
X
is unsupported.
•
ROM detects a failed processor during POST
Amber
Processor in socket
X
is in a pre-failure condition.
DIMM (amber)
Red
DIMM in slot
X
has failed.
Amber
DIMM in slot
X
is in a pre-failure condition.
DIMM (amber)
Red
One or more DIMMs have failed. Test each bank of DIMMs
by removing all other DIMMs. Isolate the failed DIMM by
replacing each DIMM in a bank with a known working
DIMM.
Overtemperature (amber)
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Fan (amber)
Amber
One fan is failed or removed.
Red
Two or more fans have failed or are missing.
Power supply (amber)
Red
Only one power supply installed and power supply in
standby.
•
Power supply fault
•
System board fault
Power supply (amber)
Amber
Redundant power supply installed and only one power
supply is functional.
•
AC power cord not plugged into redundant power
supply
•
Redundant power supply fault
Power supply (amber)
Amber
Power supply mismatch at POST or power supply mismatch
through hot add.
Rear panel components
Содержание ProLiant DL385 G5p
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 23: ...Illustrated parts catalog 23 ...
Страница 62: ...Cabling 62 Cabling SAS hard drive cabling Battery cabling for BBWC ...
Страница 79: ...Component identification 79 For more information see Hot plug fan operation Hot plug fan on page 36 ...