System Setup and Configuration for Novell NetWare 6
Configuring the Nodes
1.
Power on the shared storage (1) and wait for the controllers to initialize.
NOTE:
You must power on the Smart Array Cluster Storage before powering on the
servers. After powering on, wait until the storage system startup complete message is
displayed. It may take up to two minutes for the storage system to completely power up.
2.
Power on one server, either (2) or (3).
NOTE:
Do not use the Option ROM Configuration for Arrays (ORCA) utility to configure
the Smart Array Cluster Storage. The Array Configuration Utility must be used.
While the server boots, the ROM-Based Setup Utility (RBSU) and the ORCA
utility are automatically configured to prepare the server for the operating system
installation. To configure these utilities manually:
— Press the
F8
key when prompted during the array controller initialization to
configure the array controller using ORCA.
— Press the
F9
key when prompted during the boot process to change the server
settings, such as the settings for language and operating system, using RBSU.
The system is set up by default for the English language and a Microsoft
Windows 2000 installation. Select
NetWare 5.x/6
as the operating system.
HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide
6-3
HP CONFIDENTIAL
Codename: Sopwith Part Number: 252621-002 Last Saved On: 11/8/02 3:00 PM