Server warnings and cautions
Server warnings and cautions
WARNING:
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment, disconnect the
power cord to remove power from the server. Pressing the Power On/Standby button does not
shut off system power completely. Portions of the power supply and some internal circuitry
remain active until AC power is removed.
WARNING:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
WARNING:
WARNING:
To reduce the risk of fire or burns after removing the energy pack:
Do not disassemble, crush, or puncture the energy pack.
Do not short external contacts.
Do not dispose of the energy pack in fire or water.
Do not expose the energy pack to low air pressure as it might lead to explosion or leakage of
flammable liquid or gas.
Do not expose the energy pack to temperatures higher than 60°C (140°F).
After power is disconnected, battery voltage might still be present for 1s to 160s.
CAUTION:
CAUTION:
Protect the server from power fluctuations and temporary interruptions with a regulating UPS. This device protects the
hardware from damage caused by power surges and voltage spikes and keeps the server in operation during a power
failure.
CAUTION:
CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION:
CAUTION:
To avoid data loss, Hewlett Packard Enterprise recommends that you back up all server data before installing or
removing a hardware option, or performing a server maintenance or troubleshooting procedure.
CAUTION:
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in
this manner results in improper airflow and improper cooling that can lead to thermal damage.
Server warnings and cautions
53
Содержание ProLiant DL20 Gen10 Plus
Страница 41: ...Customer self repair 41 ...
Страница 42: ...Customer self repair 42 ...
Страница 43: ...Customer self repair 43 ...
Страница 44: ...Customer self repair 44 ...
Страница 61: ...quick release chassis ears c Repeat step a and b to remove the left ear Remove the chassis ear 61 ...
Страница 64: ...Remove the front panel cover 64 ...
Страница 81: ...To replace the component reverse the removal procedure Removing and replacing a fan 81 ...
Страница 85: ...To replace the component reverse the removal procedure Removing and replacing a LFF non hot plug drive 85 ...
Страница 93: ...To replace the component reverse the removal procedure Removing and replacing the 2 LFF drive backplane 93 ...
Страница 97: ...To replace the component reverse the removal procedure Removing and replacing the 4 SFF drive backplane 97 ...
Страница 122: ...Removing and replacing a boot device drive 122 ...
Страница 133: ...To replace the component reverse the removal procedure Removing and replacing a Flexible Slot power supply 133 ...
Страница 140: ...Heatsink replacement Removing the heatsink Installing the heatsink Heatsink replacement 140 ...
Страница 144: ...4 Install the processor air baffle 5 Install the M 2 air baffle Installing the heatsink 144 ...
Страница 146: ...Processor replacement Removing the processor Installing the processor Processor replacement 146 ...
Страница 151: ...14 Hold the processor by the edges and then lift it out of the socket Removing the processor 151 ...
Страница 155: ...7 Install the processor air baffle 8 Install the M 2 air baffle Installing the processor 155 ...
Страница 161: ...19 Hold the processor by the edges and then lift it out of the socket Removing the system board 161 ...
Страница 163: ...Removing the system board 163 ...
Страница 169: ...Troubleshooting NMI functionality Troubleshooting resources Troubleshooting 169 ...
Страница 189: ...DIMM slot location The arrow points to the front of the server DIMM slot location 189 ...
Страница 199: ...Fan numbering Fan numbering 199 ...
Страница 204: ...Cabling This chapter includes cabling guidelines and diagrams for internal component cabling Cabling 204 ...
Страница 219: ...Energy pack cabling Energy pack cabling 219 ...
Страница 224: ...M 2 SATA SSD add in card cabling 224 ...
Страница 226: ...Fan cabling Color Description Orange Fan 1 cable Blue Fan 2 cable Gold Fan 3 cable Fan cabling 226 ...
Страница 227: ...Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling 227 ...
Страница 228: ...Serial port cabling Serial port cabling 228 ...
Страница 230: ...Power supply cabling 230 ...