
Environmental specifications
Environmental specifications
Specifications
Specifications
Value
Value
Temperature range*
Temperature range*
—
Operating
10°C to 35°C (50°F to 95°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
Relative humidity (noncondensing)
—
Operating
8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
Nonoperating
5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
Altitude
Altitude
—
Operating
3050 m (10,000 ft)
This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Nonoperating
9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Standard operating support
Standard operating support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a
maximum of 3,050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of
change may be limited by the type and number of options installed.
System performance during standard operating support might be reduced if operating above 30°C (86°F).
Extended ambient operating support
Extended ambient operating support
For approved hardware configurations, the supported system inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C
(95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2,953 ft) to a
maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the Hewlett Packard Enterprise
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3,050 m (10,000 ft). The approved hardware configurations for this system are listed on the Hewlett Packard
Environmental specifications
232
Содержание ProLiant DL20 Gen10 Plus
Страница 41: ...Customer self repair 41 ...
Страница 42: ...Customer self repair 42 ...
Страница 43: ...Customer self repair 43 ...
Страница 44: ...Customer self repair 44 ...
Страница 61: ...quick release chassis ears c Repeat step a and b to remove the left ear Remove the chassis ear 61 ...
Страница 64: ...Remove the front panel cover 64 ...
Страница 81: ...To replace the component reverse the removal procedure Removing and replacing a fan 81 ...
Страница 85: ...To replace the component reverse the removal procedure Removing and replacing a LFF non hot plug drive 85 ...
Страница 93: ...To replace the component reverse the removal procedure Removing and replacing the 2 LFF drive backplane 93 ...
Страница 97: ...To replace the component reverse the removal procedure Removing and replacing the 4 SFF drive backplane 97 ...
Страница 122: ...Removing and replacing a boot device drive 122 ...
Страница 133: ...To replace the component reverse the removal procedure Removing and replacing a Flexible Slot power supply 133 ...
Страница 140: ...Heatsink replacement Removing the heatsink Installing the heatsink Heatsink replacement 140 ...
Страница 144: ...4 Install the processor air baffle 5 Install the M 2 air baffle Installing the heatsink 144 ...
Страница 146: ...Processor replacement Removing the processor Installing the processor Processor replacement 146 ...
Страница 151: ...14 Hold the processor by the edges and then lift it out of the socket Removing the processor 151 ...
Страница 155: ...7 Install the processor air baffle 8 Install the M 2 air baffle Installing the processor 155 ...
Страница 161: ...19 Hold the processor by the edges and then lift it out of the socket Removing the system board 161 ...
Страница 163: ...Removing the system board 163 ...
Страница 169: ...Troubleshooting NMI functionality Troubleshooting resources Troubleshooting 169 ...
Страница 189: ...DIMM slot location The arrow points to the front of the server DIMM slot location 189 ...
Страница 199: ...Fan numbering Fan numbering 199 ...
Страница 204: ...Cabling This chapter includes cabling guidelines and diagrams for internal component cabling Cabling 204 ...
Страница 219: ...Energy pack cabling Energy pack cabling 219 ...
Страница 224: ...M 2 SATA SSD add in card cabling 224 ...
Страница 226: ...Fan cabling Color Description Orange Fan 1 cable Blue Fan 2 cable Gold Fan 3 cable Fan cabling 226 ...
Страница 227: ...Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling 227 ...
Страница 228: ...Serial port cabling Serial port cabling 228 ...
Страница 230: ...Power supply cabling 230 ...