Physical and operating specifications 116
Table 24
Power Supply Specifications / 500 W Non-hot-plug
Item
Description
Temperature range:
Operating
Shipping
+5
°
C to +50
°
C
–40
°
C to +85
°
C
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing
Table 25
Power Supply Specifications / 750 W Hot-plug
Item
Description
Dimensions (H x W x D)
38.48 mm x 86.36 mm x 190.5 mm (1.52 in x 3.4 in x 7.5
in)
Weight (approximate)
1.36 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC/200 VAC to 240 VAC
Line frequency
47–63 Hz
Rated input current
9.10 ARMS max @ 100V
5.10 ARMS max @ 200V
BTU rating
N/A
Power supply output power:
Rated steady state power
Maximum peak power
750 W
N/A
Temperature range:
Operating
Shipping
+5
°
C to +50
°
C
–40
°
C to +85
°
C
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing