HP 750W Power Supply
Part Number - AC 750W PSU 512327-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Max Rated Output Wattage Rating
750
750
750
750
750
750
750
Nominal Input Current (A rms)
8.9
7.4
4.3
4.1
3.9
3.7
3.6
Max Rated Input Wattage Rating
(Watts)
857
847
824
825
820
820
820
Max. Rated VA (Volt-Amp)
894
884
859
859
854
854
854
Efficiency (%) at Max. Rated Output
Wattage
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
0.97
0.97
0.97
0.97
0.97
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
20
Maximum British Thermal Unit
Rating (BTU-Hr)
2925
2892
2812
2812
2797
2797
2797
HP 500W Power Supply
Part Number - AC 500W PSU 515915-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
47/63
Nominal Input Voltage (Vrms)
100
120
200
220
230
240
Maximum Rated Output Wattage
500
500
500
500
500
500
Nominal Input Current (A rms)
5.74
4.99
2.86
2.58
2.46
2.36
Max Rated Input Wattage Rating
(Watts)
568
568
562
556
556
556
Max. Rated VA (Volt-Amp)
574
574
573
567
567
567
Efficiency (%) at Max. Rated Output
Wattage
88
88
89
90
90
90
Power Factor
0.99
0.99
0.98
0.98
0.98
0.98
Leakage Current (mA)
0.42
0.50
0.81
0.91
0.95
1.00
Max. Inrush Current (A peak)
30
30
30
30
30
30
Max. Inrush Current duration (mS)
20
20
20
20
20
20
Maximum British Thermal Unit
Rating (BTU-Hr)
QuickSpecs
HP ProLiant DL160 Generation 6
Power Specifications
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 44