background image

 

Quantity

Supported

Position

Supported

Controller

500GB 6G SAS 7.2K DP

Up to 8

1-8

HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller
HP Smart Array P212/ 256 MB Controller
HP Smart Array P410/256 MB Controller
HP Smart Array P410/512 MB BBWC Controller
HP Smart Array P411/256 MB Controller
HP Smart Array P411/512 MB BBWC Controller

SAS Hot Plug 3.5" Midline (MDL) Drives

 

Quantity

Supported

Position

Supported

Controller

1TB 3G SAS 7.2K
750 3G SAS 7.2K

Up to 4

1-4

HP Smart Array P212 Controller
HP Smart Arrays P410 Controller

NOTE: Support for transfer rates up to 3 Gb/s

SAS Hot Plug SFF Enterprise (ENT) Drives

 

Quantity

Supported

Position

Supported

Controller

300GB 6G SAS 10K
300GB 3G SAS 10K
146GB 6G SAS 15K
146GB 3G SAS 15K
146GB 6G SAS 10K
146GB 3G SAS 10K
72GB 6G SAS 15K
72GB 3G SAS 10K

Up to 4

1-4

HP Smart Array P212 Controller
HP Smart Array P410 Controller

NOTE: Support for transfer rates up to 3 Gb/s

SAS Hot Plug 3.5" Enterprise (ENT) Drives

 

Quantity

Supported

Position

Supported

Controller

600GB 6G SAS 15K
450GB 6G SAS 15K
450GB 3G SAS 15K
300GB 6G SAS 15K
300GB 3G SAS 15K
146GB 3G SAS 15K

Up to 4

1-4

HP Smart Array P212 Controller
HP Smart Array P410 Controller

NOTE: Support for transfer rates up to 3 Gb/s

QuickSpecs

HP ProLiant DL160 Generation 6

Storage

DA - 13247   Worldwide QuickSpecs — Version 11 — 11.16.2009

Page 41

Содержание ProLiant DL160 Generation 6

Страница 1: ...l 8 Full height PCI Express x16 9 UID Rear Unit Identification LED 10 One GbE LAN ports for NIC 1 RJ 45 8 Eighteen DIMM slots DDR3 Registered RDIMM or Unbuffered UDIMM memory 9 Expansion Slots Non Hot Plug Models One full length full height x16 PCI Express Gen2 slot Hot Plug Models One available half length full height x16 PCI Express Gen2 slot and one internal only PCI Express Gen2 slot for inter...

Страница 2: ...ontroller HP NC362i Integrated Dual Port Gigabit Server Adapter Storage Controllers Non Hot Plug SATA Models HP Embedded SATA RAID Controller RAID 0 1 10 NOTE Transfer rate up to 3 Gb s SATA NOTE To enable RAID functionality on Embedded SATA use the HP Smart Array B110i SATA Raid controller To enable use of the B110i enter the ROM Based Setup Utility RBSU The option for enabling RAID can be functi...

Страница 3: ...support for racks with round mounting holes and tool free support for racks with square mounting holes including Compaq HP 7000 9000 10000 and HP series with an adjustment range of 26 36 Tool less access to all system components for easy in rack serviceability Customer Self Repair CSR HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performi...

Страница 4: ...20 2 26 GHz 8MB L3 Cache 80W DDR3 1066 HT Turbo 1 1 2 2 Intel Xeon Processor L5520 2 26 GHz 8MB L3 Cache 60W DDR3 1066 HT Turbo 1 1 2 2 Intel Xeon Processor E5504 2 00 GHz 4MB L3 Cache 80W DDR3 800 NOTE HT indicates that the processor model supports Intel Hyper Threading Technology NOTE Turbo indicates the maximum potential frequency increment when using Intel Turbo Boost Technology with 4 3 2 and...

Страница 5: ...h Connector Width Bus Number Device No Form Factor Notes 1 PCI Express 2 0 x16 x16 1 0 Full length full height 3 3 volts 2 PCI Express 2 0 x4 x8 6 3 Low Profile Internal Only 3 3 volts NOTE All slots can accept universal keyed PCI cards Default bus assignment Inserting cards with PCI bridges may alter the actual bus assignment number Slots are enumerated differently based on OS MS OS s enumerate f...

Страница 6: ...ion of Smart Array Advanced Pack P N 516471 B21 NOTE The addition of a Smart Array hardware based storage controller to a Non Hot Plug SATA Model is only supported for external storage Storage Diskette Drives Via USB only Optical Drives Optional SATA 9 5mm DVD ROM Optical Drive Optional SATA 9 5mm DVD RW Optical Drive Drive Bays Up to 4 Non hot plug SATA 3 5 drives Up to 4 Hot plug SAS SATA 3 5 dr...

Страница 7: ...nstalls and licenses software modules that are integrated into HP System Insight Manager HP SIM HP Insight Control for Linux serves environments requiring a Linux based management console See www hp com go ic linux HP Insight Control for Linux includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software up...

Страница 8: ... offline NOTE For more information about TPM including a white paper go to http www hp com go TPM NOTE ProLiant OS pre installed units will come with the partition required for TPM deployment NOTE The TPM key is unique to every TPM deployed server and must be retained Misplacing or losing the key could result in data loss Server Power Cords One 6 Highline IEC IEC power cord ships standard NOTE HP ...

Страница 9: ...ensure adequate airflow and to prevent damage to the equipment Front and rear doors If your 42U server rack includes closing front and rear doors you must allow 5 350 sq cm 830 square inches of hole evenly distributed from top to bottom to permit adequate airflow equivalent to the required 64 percent open area for ventilation Side The clearance between the installed rack component and the side pan...

Страница 10: ...s include coverage for the HP branded hardware options qualified for the server that are purchased at the same time or afterward and internal to the enclosure It also includes the 22 and smaller external monitors and tower UPS options up to 3kVA These items will be covered at the same service level and for the same coverage period as the server Coverage of UPS Battery is not included and standard ...

Страница 11: ...rmation visit http www hp com services proliantservices http h20219 www2 hp com services us en warranty carepack servers proliant html QuickSpecs HP ProLiant DL160 Generation 6 Standard Features DA 13247 Worldwide QuickSpecs Version 11 11 16 2009 Page 11 ...

Страница 12: ...ot of flexibility with the help of configuration tools Please visit the following URL to configure HPC Clusters with InfiniBand Gigabit Ethernet or Myrinet Interconnects http www hp com techservers clusters ucp index html HPC Interconnects InfiniBand PCI Express Generation 2 adapters Gigabit Ethernet Use embedded ports 10 Gigabit Ethernet PCI Express Generation 2 QuickSpecs HP ProLiant DL160 Gener...

Страница 13: ...rted in server models P N 490454 B21 and 490442 xx1 HP DL160G6 E5504 Hot Plug 4GB 490442 xx1 HP DL160G6 E5520 Hot Plug 6GB 490454 xx1 HP DL160G6 X5550 Hot Plug 4LFF 12GB 2P 490455 xx1 Processor s One of the following depending on model Intel Xeon Processor E5504 2 00 GHz 4MB L3 Cache 80W DDR3 800 Intel Xeon Processor E5520 2 26 GHz 8MB L3 Cache 80W DDR3 1066 HT Turbo 1 1 2 2 2 Intel Xeon Processor...

Страница 14: ...ry Code Key xx 00 U S xx 20 Brazil ONLY P N 490442 xx1 xx 29 Japan xx 37 APD xx 42 Euro xx AA PRC QuickSpecs HP ProLiant DL160 Generation 6 Models DA 13247 Worldwide QuickSpecs Version 11 11 16 2009 Page 14 ...

Страница 15: ...age use only HP ProLiant DL160 G6 Non Hot Plug SATA Rack CTO Chassis 491531 B21 Factory Integrated Model ships with HP NC362i Integrated Dual Port Gigabit Server Adapter One available full length full height PCI Express x16 Generation 2 slot One Highline IEC Power Cord 6 Non Hot Plug Fans Rack 1U 1 75 in 4 45 cm Tool less Fixed Rails Hot Plug Model HP ProLiant DL160 G6 Hot Plug SAS SATA Rack CTO C...

Страница 16: ...26 GHz 8MB L3 Cache 80W DDR3 1066 HT Turbo 1 1 2 2 FIO NOTE If 2 processors are desired select one 490459 L21 and one 490459 B21 490459 L21 Intel Xeon Processor L5520 2 26 GHz 8MB L3 Cache 60W DDR3 1066 HT Turbo 1 1 2 2 FIO NOTE If 2 processors are desired select one 491507 L21 and one 491507 B21 491507 L21 Intel Xeon Processor E5504 2 00 GHz 4MB L3 Cache 80W DDR3 800 FIO NOTE If 2 processors are ...

Страница 17: ...anks per memory channel maximum of 2 quad rank DIMMs per channel Hard Drive NOTE The components of a storage subsystem e g the drive the HBA controller and the server backplane should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components NOTE Hard drives have either a one year or three year warranty refer to the specific ha...

Страница 18: ...l P N 491532 B21 in Step 1 HP 8SFF Hard Drive Cage Backplane G6 FIO 515938 B21 HP 2 HDD Backplane G6 FIO Kit NOTE Supports LFF hard drives only 518593 B21 HP 4HDD Hot Plug Backplane G6 Kit NOTE Supports LFF hard drives only 512181 B21 Power Supplies CAUTION Many HP ProLiant Servers now offer new power options including Common Slot Power Supplies These power supplies come in multiple power ratings ...

Страница 19: ...ion NOTE For additional Core Options and Additional Options please refer to the Options section below QuickSpecs HP ProLiant DL160 Generation 6 Configuration Information Factory Integrated Models DA 13247 Worldwide QuickSpecs Version 11 11 16 2009 Page 19 ...

Страница 20: ...L3 Cache 80W DDR3 1066 HT Turbo 1 1 2 2 490459 B21 Intel Xeon Processor E5504 2 00 GHz 4MB L3 Cache 80W DDR3 800 490457 B21 Intel Xeon Processor L5520 2 26 GHz 8MB L3 Cache 60W DDR3 1066 HT Turbo 1 1 2 2 491507 B21 NOTE HT indicates that the processor model supports Intel Hyper Threading Technology NOTE Turbo indicates the maximum potential frequency increment when using Intel Turbo Boost Technolo...

Страница 21: ...the system bandwidth will be negotiated down to an acceptable level for all components NOTE Hard drives have either a one year or three year warranty refer to the specific hard drive QuickSpecs for details SATA Hot Plug SFF Midline MDL Drives HP 500GB 3G SATA 7 2K 2 5in MDL HDD 507750 B21 HP 160GB 3G SATA 7 2K 2 5in MDL HDD 530888 B21 SATA Hot Plug SFF Entry ETY Drives HP 250GB 3G SATA 5 4K SFF ET...

Страница 22: ... Enterprise ENT Drives HP 300GB 6G SAS 10K SFF DP ENT HDD 507127 B21 HP 300GB 3G SAS 10K SFF DP ENT HDD 492620 B21 HP 146GB 6G SAS 10K SFF DP ENT HDD 507125 B21 HP 146GB 3G SAS 10K SFF DP ENT HDD 418367 B21 HP 146GB 6G SAS 15K SFF DP ENT HDD 512547 B21 HP 146GB 3G SAS 15K SFF DP ENT HDD 504062 B21 HP 72GB 6G SAS 15K SFF DP ENT HDD 512545 B21 HP 72GB 3G SAS 15K SFF DP ENT HDD 418371 B21 HP 72GB 3G ...

Страница 23: ...pter 435508 B21 HP NC375T PCI Express Quad Port Gigabit Server Adapter 538696 B21 10 Gigabit Ethernet Adapters HP NC522SFP Dual Port 10GbE Server Adapter 468332 B21 NOTE A minimum of two Gigabtyes 2GB of server memory is required for each NC522SFP adapter NOTE Direct Attach Cable DAC for copper environments or fiber transceivers and cables for fiber optic environments must be purchased separately ...

Страница 24: ...will receive a license entitlement certificate which must be redeemed online or via fax in order to obtain the license activation key s Includes one year of 24 x 7 HP Software Technical Support Service NOTE For additional License Kits including electronic licensing options please see the QuickSpecs at http h18000 www1 hp com products quickspecs 13019_div 13019_div html HP Insight Control server de...

Страница 25: ...o the Non Hot Plug Model Chassis P N 491531 B21 is supported for external storage ONLY NOTE To utilize the internal only slot the HP Smart Array P410 Controller must be selected The selection of the HP Smart Array P212 Controller for internal and external connectivity will require the use of the Full Length Full Height PCI E x16 slot NOTE With the HP Smart Array P410 Controller the addition of the...

Страница 26: ... e G2 Dual Port HCA 517721 B21 HP 4X QDR PCI e G2 QLogic InfiniBand Dual Port HCA 583211 B21 HP IB 4X QDR CX 2 PCI e G2 Dual Port HCA 592520 B21 HP IB 4X DDR CX 2 PCI e G2 Dual Port HCA 592521 B21 NOTE For HPC interconnect adapters please see the HPC Interconnect section of this QuickSpecs Tape Storage NOTE For the complete listing of Tape Drive offerings please see http www hp com products1 stora...

Страница 27: ...dedicated HBA for SAS tape library connection NOTE Please see the QuickSpecs for Technical Specifications and additional information http www hp com go automation needed to create a complete solution reference current compatibility information at http www hp com go ebs Disk Based Backup RDX Removable Disk Backup HP StorageWorks RDX320 External Removable Disk Backup System NOTE 320GB of Disk Storag...

Страница 28: ...to ProLiant servers AH627A HP StorageWorks Modular Smart Array MSA SAN Storage Arrays HP StorageWorks 50 Modular Smart Array 364430 B21 NOTE Rack mountable 10 SFF drive enclosure with single I O module redundant hot plug power supplies and hot plug fans NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12245_div 12245...

Страница 29: ... JPN AF424A HP R3000 VA UPS 2U Low Voltage L5 30 JPN AF425A NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 10671_div 10671_div html Worldwide HP R3000v Uninterruptible Power System HP R3000v UPS NOTE The R3000v is available in China and India only AF444A NOTE Please see the QuickSpecs for Technical Specifications a...

Страница 30: ... NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12118_div 12118_div html Worldwide Modular PDUs 1U 0U Up to 28 outlets NOTE 1U 0U mounting brackets shipped with the unit optimized for 10000 G2 and 9000 series racks Fixed Cord Extension Bars NOTE Two extension bar sticks each with 7 C13 plugs 351655 B21 3 6kVA Model...

Страница 31: ...ch KVM 0 x 2 x 16 port AF617A HP 1x4 Console Switch AF611A HP USB Server Console Cable 6 foot 2 Pack NOTE required for supporting USB peripherals AF613A NOTE Cat5e cables are required to connect Interface Adapters to Console Switches Cat5e cables can be found at the following URL http www hp com go kvm HP Serial Console Server Options HP 16 Port Serial Console Server worldwide AF101A HP 48 Port Se...

Страница 32: ...769 B21 must be used 536769 B21 Service and Support Offerings HP Care Pack Services Hardware Services 4 Hour On site Service 13 Hour x 5 Day Coverage 3 Years Electronic U9509E 24 Hour x 7 Day Coverage 3 Years Electronic U9510E Hardware Services 6 Hour Call to Repair On Site Service 6 Hour Call to Repair On Site Service 7 Day x 24 Hour Coverage 3 Years Electronic U9511E Hardware Services 9 Hour x 5...

Страница 33: ...processor is not installed If only one processor is installed in a 2CPU system only half of the DIMM slots are available To maximize performance balance the total memory capacity between all installed processors It is not required but it is recommended to load the channels similarly if possible You can only have up to eight 8 ranks installed per channel You can only install two quad rank DIMMs per...

Страница 34: ...other channels you run at 1066MHz If you install 3DPC in one channel if applicable and 1DPC in all other channels you run at 800MHz 95 Watt CPU s are required for 1333MHz DIMM speeds All other CPU s are capable of up to 1066MHz References to the above MHz speeds are for the various speeds of DDR3 DIMMs 1333 refers to DDR3 1333 etc DIMM slot and configuration diagrams Basic memory slot population d...

Страница 35: ... 10600 RDIMMs 6x 8GB dual rank PC3 10600 or PC3 8500 RDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G 8GB DIMM 1 G empty Chnl 1 2 D 8GB DIMM 2 D empty 3 A 2GB DIMM 3 A empty Chnl 2 4 H 8GB DIMM 4 H empty Chnl 2 5 E 8GB DIMM 5 E empty 6 B 2GB DIMM 6 B empty Chnl 3 7 I 8GB DIMM 7 I empty Chnl 3 8 F 8GB DIMM 8 F empty 9 C 2GB DIMM 9 C empty Standard memory replaced with optiona...

Страница 36: ... rank PC3 10600 UDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G empty 1 G empty Chnl 1 2 D 2GB DIMM 2 D empty 3 A 2GB DIMM 3 A empty Chnl 2 4 H empty 4 H empty Chnl 2 5 E 2GB DIMM 5 E empty 6 B 2GB DIMM 6 B empty Chnl 3 7 I empty 7 I empty Chnl 3 8 F 2GB DIMM 8 F empty 9 C 2GB DIMM 9 C empty Standard memory replaced with optional memory 2 CPU model RDIMM maximum configurati...

Страница 37: ...ng of twelve 12 2GB dual rank PC3 10600 UDIMMs CPU1 CPU2 slot population order slot population order Chnl 1 1 G empty 1 G empty Chnl 1 2 D 2GB DIMM 2 D 2GB DIMM 3 A 2GB DIMM 3 A 2GB DIMM Chnl 2 4 H empty 4 H empty Chnl 2 5 E 2GB DIMM 5 E 2GB DIMM 6 B 2GB DIMM 6 B 2GB DIMM Chnl 3 7 I empty 7 I empty Chnl 3 8 F 2GB DIMM 8 F 2GB DIMM 9 C 2GB DIMM 9 C 2GB DIMM NOTE Capacity references are rounded to t...

Страница 38: ...HP 1GB 1Rx8 PC3 10600E 9 Kit 500668 B21 HP 2GB 2Rx8 PC3 10600E 9 Kit 500670 B21 NOTE All DDR3 memory option kits consist of one DIMM per kit For detailed memory configuration rules and guidelines please use the Online DDR3 Memory Configuration Tool www hp com go ddr3memory configurator NOTE Kits described as LP include Low Power DIMMs For more information on ProLiant Energy Efficient Features see ...

Страница 39: ...ATA Hot Plug SFF Midline MDL Drives Quantity Supported Position Supported Controller 500GB 3GSATA 7 2K 160GB 3G SATA 7 2K Up to 4 1 4 HP Embedded SATA RAID Controller NOTE Transfer rate 1 5 Gb s SATA SATA Hot Plug SFF Entry ETY Drives Quantity Supported Position Supported Controller 250GB 3G SATA 5 4K 120GB 1 5G SATA 5 4K Up to 4 1 4 HP Embedded SATA RAID Controller NOTE Transfer rate 1 5 Gb s SAT...

Страница 40: ...troller HP Smart Array P400 256MB Controller HP Smart Array P400 512MB BBWC Controller HP Smart Array P600 256 BBWC Controller HP Smart Array P800 512 BBWC Controller SATA Hot Plug 3 5 Midline MDL Solid State Drives Quantity Supported Position Supported Controller 60GB 3 0G SATA SSD 120GB 3 0G SATA SSD Up to 4 1 4 HP Smart Array E200i 64MB Controller HP Smart Array E200i 128 BBWC Controller HP Sma...

Страница 41: ...er rates up to 3 Gb s SAS Hot Plug SFF Enterprise ENT Drives Quantity Supported Position Supported Controller 300GB 6G SAS 10K 300GB 3G SAS 10K 146GB 6G SAS 15K 146GB 3G SAS 15K 146GB 6G SAS 10K 146GB 3G SAS 10K 72GB 6G SAS 15K 72GB 3G SAS 10K Up to 4 1 4 HP Smart Array P212 Controller HP Smart Array P410 Controller NOTE Support for transfer rates up to 3 Gb s SAS Hot Plug 3 5 Enterprise ENT Drive...

Страница 42: ...ted Controller Controller HBA Option Kit Part Number HP StorageWorks SCSI Tape Drives External LTO 1 Ultrium 232 LTO 2 Ultrium 448 LTO 3 Ultrium 920 LTO 3 Ultrium 960 LTO4 Ultrium 1760 LTO 4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack Mount Kit 3U Rack Mount Kit External HP SC11Xe Host Bus Adapter 412911 B21 HP StorageWorks USB Tape Drives External DAT 40 USB DAT 72 USB DAT 160 USB DAT 320 USB 1U U...

Страница 43: ...ro Memory ZM Controller 462828 B21 HP StorageWorks Fibre Tape Automation External MSL2024 MSL4048 MSL8096 MSL6000 External Please consult the EBS connectivity matrix at http www hp com go ebs for detailed connectivity information N A HP StorageWorks RDX Removable Disk Backup System External RDX160 RDX320 RDX500 External USB 2 0 port N A HP StorageWorks D2D Backup Systems D2D120 D2D130 D2D2500i D2D...

Страница 44: ...0 Maximum British Thermal Unit Rating BTU Hr 2925 2892 2812 2812 2797 2797 2797 HP 500W Power Supply Part Number AC 500W PSU 515915 B21 Option Kit Input Voltage Range Vrms 100 to 240 Frequency Range Nominal Hz 47 63 Nominal Input Voltage Vrms 100 120 200 220 230 240 Maximum Rated Output Wattage 500 500 500 500 500 500 Nominal Input Current A rms 5 74 4 99 2 86 2 58 2 46 2 36 Max Rated Input Wattag...

Страница 45: ...put Voltage Range Vrms 100 to 240 Frequency Range Nominal Hz 50 60 Nominal Input Voltage Vrms 100 120 200 208 220 230 240 Maximum Rated Output Wattage 320 320 360 360 360 360 360 Nominal Input Current A rms 4 15 3 41 2 23 2 16 2 03 1 94 1 86 Max Rated Input Wattage Rating Watts 412 406 445 445 444 443 443 Max Rated VA Volt Amp 413 407 447 447 446 446 445 Efficiency at Max Rated Output Wattage 77 4...

Страница 46: ...C IEC power cord ships standard NOTE HP ProLiant DL servers no longer ship standard with NEMA power cords 163719 002 that allow connection to 110V US wall outlets in a home or office ProLiant DL servers are primarily connected to PDU s in data center racks so they now ship standard with only a PDU power cord 416151 B21 If a user wishes to power a ProLiant DL server using a 110V receptacle NEMA 15 ...

Страница 47: ... ratings use the Power Advisor which is available via the online tool located at URL www hp com go proliant energy efficient Or www hp com go hppoweradvisor Click on the system of interest Example DL160 G6 Follow the instructions of the next screens Power Supply Output per power supply Rated Steady State Power 500 Watts at 100 VAC 500 Watts at 200 VAC Maximum Peak Power See Power Specifications Ta...

Страница 48: ...eighted sound power levels LWAd and declared average bystander position A Weighted sound pressure levels LpAm when the product is operating in a 23 C ambient environment Noise emissions were measured in accordance with ISO 7779 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle LWAd 6 3B LpAm 48dBA Operating LWAd 6 3B LpAm 48dBA Emissions Classification EMC FCC Rating Class A Normative...

Страница 49: ...work Interface Integrated 10 100 1000BASE T Transceiver Combines a triple speed IEEE 802 3TM Compliant Media Access Controller MAC with a triple speed Ethernet transceiver Data Transfer Method Compliant to x1 PCIe Specification Network Transfer Rate 10Base T Half Duplex 10 Mb s 10Base T Full Duplex 20 Mb s 100Base TX Half Duplex 100 Mb s 100Base TX Full Duplex 200 Mb s 1000Base TX Half and Full Du...

Страница 50: ...ttp www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly inst...

Отзывы: