HP ProLiant BL660c Gen9 Server Blade 

Maintenance and Service Guide 

Abstract 

This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and 

software. This guide is for an experienced service technician.   

 

 

Part Number: 798323-001 
June 2015 

Edition: 1 

Содержание ProLiant BL660c Gen9

Страница 1: ...e Guide Abstract This guide describes identification and maintenance procedures diagnostic tools specifications and requirements for hardware components and software This guide is for an experienced service technician Part Number 798323 001 June 2015 Edition 1 ...

Страница 2: ... and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Microsoft and Windows are U S registered trademarks of Microsoft group of companies Intel and Xeon are trademarks of Intel Corporation in the United States and other countries microSD is a trademark or registered trademark of...

Страница 3: ... blank 27 Drive 27 Enclosure connector covers 28 Mezzanine assembly 29 Mezzanine options 30 FlexibleLOM 32 Storage controller 33 Heatsink blank 34 DIMM baffles 35 DIMMs 37 HP Smart Storage Battery 38 Drive backplane 39 System battery 40 Heatsink 41 Processor 43 System board 47 HP Trusted Platform Module 54 Troubleshooting 55 Troubleshooting resources 55 Diagnostic tools 56 Product QuickSpecs 56 HP...

Страница 4: ...s 65 System board components 66 System maintenance switch 67 Mezzanine connector definitions 67 DIMM slot locations 68 DIMM identification 68 HP c Class Blade SUV Cable 69 Cabling 70 Cabling overview 70 HP Smart Storage Battery cabling 70 Direct connect SATA cabling 71 SAS cabling 72 Using the HP c Class Blade SUV Cable 72 Connecting locally to a server blade with video and USB devices 72 Accessin...

Страница 5: ...n will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is required to return the defective part to HP you must ship the defective part back to HP within a defined period of time normally five 5 business days The defective part must be returned with the associated documentation in the pro...

Страница 6: ...ine la société de courses ou le transporteur à utiliser Pour plus d informations sur le programme CSR de HP contactez votre Mainteneur Agrée local Pour plus d informations sur ce programme en Amérique du Nord consultez le site Web HP http www hp com go selfrepair Service de garantie pièces seules Votre garantie limitée HP peut inclure un service de garantie pièces seules Dans ce cas les pièces de ...

Страница 7: ... Self Repair um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen Wenn HP oder ein HP Servicepartner bei der Diagnose feststellt dass das Produkt mithilfe eines CSR Teils repariert werden kann sendet Ihnen HP dieses Bauteil zum Austausch direkt zu CSR Teile werden in zwei Kategorien unterteilt Zwingend Teile für die das Customer Self Repair Verfa...

Страница 8: ...tegorías Obligatorio componentes para los que la reparación por parte del usuario es obligatoria Si solicita a HP que realice la sustitución de estos componentes tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio Opcional componentes para los que la reparación por parte del usuario es opcional Estos componentes también están diseñados para que puedan ser r...

Страница 9: ...orieën CSR onderdelen Verplicht Onderdelen waarvoor reparatie door de klant verplicht is Als u HP verzoekt deze onderdelen voor u te vervangen worden u voor deze service reiskosten en arbeidsloon in rekening gebracht Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te v...

Страница 10: ...ependendo do tipo de serviço de garantia destinado ao produto OBSERVAÇÃO Algumas peças da HP não são projetadas para o reparo feito pelo cliente A fim de cumprir a garantia do cliente a HP exige que um técnico autorizado substitua a peça Essas peças estão identificadas com a marca No Não no catálogo de peças ilustrado Conforme a disponibilidade e o local geográfico as peças CSR serão enviadas no p...

Страница 11: ...Customer self repair 11 No caso desse serviço a substituição de peças CSR é obrigatória Se desejar que a HP substitua essas peças serão cobradas as despesas de transporte e mão de obra do serviço ...

Страница 12: ...Customer self repair 12 ...

Страница 13: ...Customer self repair 13 ...

Страница 14: ...Customer self repair 14 ...

Страница 15: ... information see the HP PartSurfer website http partsurfer hp com Item Description Spare part number Customer self repair on page 5 Mechanical components 1 Access panel 806557 001 Mandatory1 2 Drive blank SFF 675607 001 Mandatory1 3 DIMM baffles a DIMM baffle right 808191 001 Mandatory1 b DIMM baffle left 808192 001 Mandatory1 c DIMM baffle center 808190 001 Mandatory1 ...

Страница 16: ...nk 777687 001 Optional2 b Processor 3 and 4 heatsink 777686 001 Optional2 c Blank 670027 001 Mandatory1 8 Hard drives a 600 GB SAS SFF 10 000 rpm 12G 781516 B21 Mandatory1 b 1 2 TB SAS SFF 10 000 rpm 12G 781578 001 Mandatory1 c 300 GB SAS SFF 10 000 rpm 12G 785067 B21 Mandatory1 d 900 GB SAS SFF 10 000 rpm 12G 785411 001 Mandatory1 e 1 8 TB SAS SFF 10 000 rpm 12G 791055 001 Mandatory1 f 300 GB SAS...

Страница 17: ...120 GB SATA VE SFF 6G 765013 001 Mandatory1 h 240 GB SATA VE SFF 6G 765014 001 Mandatory1 i 480 GB SATA VE SFF 6G 765015 001 Mandatory1 j 800 GB SATA VE SFF 6G 765016 001 Mandatory1 k 100 GB SATA ME SFF 6G 692164 001 Mandatory1 l 200 GB SATA ME SFF 6G 692165 001 Mandatory1 m 400 GB SATA ME SFF 6G 692166 001 Mandatory1 n 800 GB SATA ME SFF 6G 692167 001 Mandatory1 o 120 GB SATA VE SFF 6G 718136 001...

Страница 18: ...01 Mandatory1 11 Storage controller HP Smart Array P246br Controller 750000 001 Mandatory1 12 Drive backplane 795117 001 Optional2 13 System I O board with base pan 759483 001 Optional2 14 Trusted Platform Module 744411 001 No3 Mezzanine and FlexibleLOM options 15 Controllers a HP LPe1605 16Gb Fibre Channel HBA for BladeSystem c Class 718577 001 Mandatory1 b HP QMH2672 16Gb Fibre Channel Host Bus ...

Страница 19: ...s pour lesquelles la réparation par le client est facultative Ces pièces sont également conçues pour permettre au client d effectuer lui même la réparation Toutefois si vous demandez à HP de remplacer ces pièces l intervention peut ou non vous être facturée selon le type de garantie applicable à votre produit 3 No Non Certaines pièces HP ne sont pas conçues pour permettre au client d effectuer lui...

Страница 20: ...ustomer Self Repair verplicht is Als u HP verzoekt deze onderdelen te vervangen komen de reiskosten en het arbeidsloon voor uw rekening 2 Optional Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afha...

Страница 21: ...Illustrated parts catalog 21 ...

Страница 22: ...ic damage Avoid hand contact by transporting and storing products in static safe containers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly grounded when touching a static sensitive component or assembly Server b...

Страница 23: ...ion WARNING To reduce the risk of electric shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle This symbol indicates the presence of a hot surface or hot component If this surface is contacted the potential for injury exists WARNING To reduce the risk of injury from a hot component allow the surface to cool before touching 9 16 kg 20 20...

Страница 24: ...before the server blade enters standby mode Use the Onboard Administrator CLI to execute one of the following commands o poweroff server bay number This command initiates a controlled shutdown of applications and the OS before the server blade enters standby mode o poweroff server bay number force This form of the command forces the server blade to enter standby mode without properly exiting appli...

Страница 25: ...sk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components properly ground the server blade before beginning any installation procedure Improper grounding can cause ESD damage Installing a server blade 1 Remove the connector covers ...

Страница 26: ...procedures 26 2 Open the server blade latch 3 Install the server blade Access panel To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Press the access panel release button ...

Страница 27: ...lace the component squeeze the release latch and slide the drive blank into the bay until it clicks into place Drive To remove the component 1 Determine the status of the drive from the drive LED definitions Hot plug drive LED definitions on page 65 2 Back up all server blade data on the drive 3 Remove the drive To replace the component CAUTION To prevent improper cooling and thermal damage do not...

Страница 28: ...re the drive 2 Install the drive 3 Determine the status of the drive from the drive LED definitions Hot plug drive LED definitions on page 65 Enclosure connector covers To remove the component 1 Place the server blade on a flat level work surface ...

Страница 29: ...erse the removal procedure Mezzanine assembly To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Remove the mezzanine assembly To replace the component ...

Страница 30: ...system board 2 Press down firmly on the mezzanine assembly handles and then close the mezzanine assembly latch 3 Install the access panel Access panel on page 26 4 Install the server blade Installing a server blade on page 25 Mezzanine options To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface ...

Страница 31: ...Removal and replacement procedures 31 6 Remove the mezzanine card from the mezzanine assembly To replace the component 1 Align the mezzanine card with the guide pins on the mezzanine assembly ...

Страница 32: ... board and then install the mezzanine assembly on the system board 4 Press down firmly on the mezzanine assembly handles and then close the mezzanine assembly latch 5 Install the access panel Access panel on page 26 6 Install the server blade Installing a server blade on page 25 FlexibleLOM To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Plac...

Страница 33: ... FlexibleLOM from the system board To replace the component reverse the removal procedure Storage controller To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Disconnect the SAS cable from the storage controller and the drive backplane ...

Страница 34: ...t reverse the removal procedure Heatsink blank To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Do one of the following o Remove the storage controller Storage controller on page 33 ...

Страница 35: ...r blade and the enclosure install all DIMM baffles in the proper location after adding or replacing DIMMs DIMM baffles that are missing or installed incorrectly can compromise server blade and enclosure cooling The server blade contains three DIMM baffles 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the...

Страница 36: ...Removal and replacement procedures 36 o Center DIMM baffle o Right DIMM baffle ...

Страница 37: ...nt 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Remove the mezzanine assembly Mezzanine assembly on page 29 6 Remove the FlexibleLOM FlexibleLOM on page 32 7 Remove the storage controller Storage controller on page 33 8 Disconnect the direct connect SATA cables...

Страница 38: ...58 HP Smart Storage Battery To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Remove the left DIMM baffle DIMM baffles on page 35 6 Remove the HP Smart Storage Battery To replace the component reverse the removal procedure ...

Страница 39: ...emove all drive blanks Drive blank on page 27 CAUTION Remove all drives and drive blanks before removing the drive backplane 7 Do one of the following o Remove the storage controller Storage controller on page 33 o Disconnect the direct connect SATA cable Direct connect SATA cabling on page 71 8 Remove the internal USB drive if installed To locate the internal USB connector see System board compon...

Страница 40: ...plane from the front panel drive cage assembly To replace the component reverse the removal procedure System battery If the server blade no longer automatically displays the correct date and time then replace the battery that provides power to the real time clock Under normal use battery life is 5 to 10 years ...

Страница 41: ...default configuration After replacing the battery reconfigure the system through RBSU To remove the component 1 Power down the server blade on page 23 2 Remove the server blade on page 24 3 Place the server blade on a flat level work surface 4 Remove the access panel Access panel on page 26 5 Locate the battery on the system board System board components on page 66 6 Remove the battery To replace ...

Страница 42: ...age 33 o Disconnect the direct connect SATA cables Direct connect SATA cabling on page 71 NOTE Only remove the storage controller if the processor 1 or processor 3 heatsink is being removed 6 Remove the heatsink To replace the component 1 Clean the old thermal grease from the processor with the alcohol swab Allow the alcohol to evaporate before continuing 2 Apply all the grease to the top of the p...

Страница 43: ...ning the screws until the heatsink is seated properly 5 Install the storage controller Storage controller on page 33 or connect the direct connect SATA cable Direct connect SATA cabling on page 71 6 Install the access panel Access panel on page 26 7 Install the server blade Installing a server blade on page 25 Processor WARNING To reduce the risk of personal injury from hot surfaces allow the driv...

Страница 44: ...e ESD damage IMPORTANT Processor sockets 1 and 2 must always be populated If either processor socket is empty the server blade does not power up To remove the component 1 Update the system ROM Locate and download the latest ROM version from the HP website http www hp com support Follow the instructions on the website to update the system ROM 2 Power down the server blade on page 23 3 Remove the se...

Страница 45: ...LY DAMAGED To avoid damage to the system board do not touch the processor or the processor socket contacts 9 Remove the processor from the processor retaining bracket To replace the component CAUTION To avoid damage to the system board processor socket and screws do not overtighten the heatsink screws ...

Страница 46: ...ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board do not touch the processor or the processor socket contacts CAUTION Do not press down on the processor Pressing down on the processor may cause damage to the processor socket and the system board Press only in the area indicated on the processor retaining bracket 2 Close the processor retaining bracket When the processor is in...

Страница 47: ...retaining bracket 4 Align and install the heatsink Alternate tightening the screws until the heatsink is seated properly 5 Install the storage controller Storage controller on page 33 or connect the direct connect SATA cable Direct connect SATA cabling on page 71 6 Install the access panel Access panel on page 26 7 Install the server blade Installing a server blade on page 25 System board ...

Страница 48: ...anks Drive blank on page 27 7 Remove the mezzanine assembly Mezzanine assembly on page 29 8 Remove the FlexibleLOM FlexibleLOM on page 32 9 Do one of the following o Remove the storage controller Storage controller on page 33 o Disconnect the direct connect SATA cable Direct connect SATA cabling on page 71 10 Remove the internal USB drive if installed To locate the internal USB connector see Syste...

Страница 49: ...nk Heatsink on page 41 17 Open each of the processor locking levers in the order indicated and then open the processor retaining bracket CAUTION THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board do not touch the processor or the processor socket contacts ...

Страница 50: ...onnector covers from the new system board and install the enclosure connector covers on the damaged system board Enclosure connector covers on page 28 To replace the system board 1 Place the new server blade system board with base pan on a flat level surface IMPORTANT Install all components in the same configuration prior to removing the system board 2 If the server blade had less than four proces...

Страница 51: ...ent procedures 51 3 Open each of the processor locking levers in the order indicated and then open the processor retaining bracket 4 Remove the clear processor socket cover Retain the processor socket cover for future use ...

Страница 52: ...r may cause damage to the processor socket and the system board Press only in the area indicated on the processor retaining bracket CAUTION Close and hold down the processor cover socket while closing the processor locking levers The levers should close without resistance Forcing the levers closed can damage the processor and socket requiring system board replacement 6 Close the processor retainin...

Страница 53: ...system board 9 Clean the old thermal grease from the heatsink with the alcohol swab Allow the alcohol to evaporate before continuing 10 Apply all the grease to the top of the processor in the following pattern to ensure even distribution 11 Install the heatsink Heatsink on page 41 12 Install the front panel drive cage assembly 13 Install all DIMMs DIMMs on page 37 14 Install all DIMM baffles DIMM ...

Страница 54: ...ppears The serial number should only be modified by qualified service personnel This value should always match the serial number located on the chassis 4 Press the Enter key to clear the warning 5 Enter the serial number and press the Enter key 6 Select Product ID The following warning appears Warning The Product ID should ONLY be modified by qualified service personnel This value should always ma...

Страница 55: ...ort Gen9_TSG_es German http www hp com support Gen9_TSG_de Japanese http www hp com support Gen9_TSG_ja Simplified Chinese http www hp com support Gen9_TSG_zh_cn The HP ProLiant Gen9 Troubleshooting Guide Volume II Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades To view the guide select ...

Страница 56: ...ng Access a high performance and secure Integrated Remote Console to the server from anywhere in the world if you have a network connection to the server Use the shared NET Integrated Remote Console to collaborate with up to four server administrators Remotely mount high performance Virtual Media devices to the server blade Securely and remotely control the power state of the managed server blade ...

Страница 57: ...d or passed through by the operating system The data that is collected is managed according to the HP Data Privacy policy For more information see the HP website http www hp com go privacy The Active Health System in conjunction with the system monitoring provided by Agentless Management or SNMP Pass thru provides continuous monitoring of hardware and configuration changes system status and servic...

Страница 58: ...wer Application From within the iLO web interface From within HP Insight Diagnostics on page 60 HP UEFI System Utilities The HP UEFI System Utilities is embedded in the system ROM The UEFI System Utilities enable you to perform a wide range of configuration activities including Configuring system devices and installed options Enabling and disabling system features Displaying system information Sel...

Страница 59: ...nostics option see the HP UEFI System Utilities User Guide for HP ProLiant Gen9 Servers on the HP website http www hp com go ProLiantUEFI docs Re entering the server serial number and product ID After you replace the system board you must re enter the server blade serial number and the product ID 1 During the server blade startup sequence press the F9 key to access UEFI System Utilities 2 Select t...

Страница 60: ...en data gathering intervals the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration Survey functionality is installed with every Intelligent Provisioning assisted HP Insight Diagnostics installation or it can be installed through the SPP HP Insight Remote Support HP strongly recommends that you register your device ...

Страница 61: ...t USB 3 0 speeds at all times including the pre boot environment when in UEFI Boot Mode This mode should not be used with operating systems that do not support USB 3 0 If operating in Legacy Boot BIOS Mode the USB 3 0 ports cannot function in the pre boot environment and are not bootable Disabled If configured for Disabled USB 3 0 capable devices function at USB 2 0 speeds at all times The pre OS ...

Страница 62: ...nt DL980 Servers or panic A system fail safe timer the ASR timer starts when the System Management driver also known as the Health Driver is loaded When the operating system is functioning properly the system periodically resets the timer However when the operating system fails the timer expires and restarts the server ASR increases server availability by restarting the server within a specified t...

Страница 63: ...y 2 5 External USB 6 Drive Bay 3 7 Drive Bay 4 8 Server blade release lever 9 Server blade release button The SUV connector and the HP c Class Blade SUV Cable are used for some server blade configuration and diagnostic procedures Front panel LEDs and buttons Item Description Status 1 Health status LED bar Solid Green Normal System is powered on Flashing Green Power On Standby button service is bei...

Страница 64: ...mation see Power fault LEDs on page 64 Facility power is not present power cord is not attached no power supplies are installed power supply failure has occurred or the power button cable is disconnected Power fault LEDs The following table provides a list of power fault LEDs and the subsystems that are affected Not all power faults are used by all servers Subsystem LED behavior System board 1 fla...

Страница 65: ... the drive Removing the drive causes one or more of the logical drives to fail Off Removing the drive does not cause a logical drive to fail 4 Drive status Solid green The drive is a member of one or more logical drives Flashing green The drive is rebuilding or performing a RAID migration strip size migration capacity expansion or logical drive extension or is erasing Flashing amber green The driv...

Страница 66: ...2 10 Mezzanine connector 1 Type A mezzanine only 11 Mezzanine connector 2 Type A or Type B mezzanine 12 FlexibleLOM 2 connectors 2 13 MicroSD connector 14 FlexibleLOM 1 connectors 2 15 Mezzanine connector 3 Type A or Type B mezzanine 16 Processor 2 17 Processor 2 DIMM slots 8 18 Processor 4 19 Processor 4 DIMM slots 8 20 System maintenance switch 21 Server blade release lever 22 TPM module connect...

Страница 67: ...onfiguration as invalid S7 Off Off Set default boot mode to UEFI On Set default boot mode to legacy S8 Reserved S9 Reserved S10 Reserved S11 Reserved S12 Reserved To access the redundant ROM set S1 S5 and S6 to on When the system maintenance switch position 6 is set to the On position the system is prepared to erase all system configuration settings from both CMOS and NVRAM CAUTION Clearing CMOS a...

Страница 68: ...ssignments for population order and the slot numbers designate the DIMM slot ID for spare replacement DIMM identification To determine DIMM characteristics use the label attached to the DIMM and the following illustration and table Item Description Definition 1 Capacity 8 GB 16 GB 32 GB 2 Rank 1R Single rank 2R Dual rank 4R Quad rank 3 Data width x4 4 bit ...

Страница 69: ...ications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs HP c Class Blade SUV Cable Item Connector Description 1 Server blade For connecting to the SUV connector on the server blade front panel 2 Serial For trained personnel to connect a null modem serial cable and perform advanced diagnostic procedures 3 USB For connecting up to two USB ...

Страница 70: ...ing 70 Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance HP Smart Storage Battery cabling ...

Страница 71: ...abling 71 Direct connect SATA cabling A single direct connect SATA device is cabled on the left side of the server blade Two direct connect SATA devices are cabled as shown in the following illustration ...

Страница 72: ...SB devices USB hub USB keyboard USB mouse USB CD DVD ROM drive Numerous configurations are possible This section offers two possible configurations For more information see USB support on page 60 Accessing a server blade with local KVM For this configuration a USB hub is not necessary To connect additional devices use a USB hub CAUTION Before disconnecting the SUV cable from the connector always s...

Страница 73: ...configuring a server blade or loading software updates and patches from a USB CD DVD ROM Use a USB hub when connecting a USB CD ROM drive to the server blade The USB hub provides additional connections 1 Open the serial label pull tab and connect the HP c Class Blade SUV cable to the server blade 2 Connect the video connector to a monitor 3 Connect a USB hub to one USB connector 4 Connect the foll...

Страница 74: ...Cabling 74 o USB mouse Item Description 1 Monitor 2 USB CD DVD ROM drive 3 USB keyboard 4 USB hub 5 USB mouse 6 HP c Class Blade SUV Cable ...

Страница 75: ...ng of 1 C per 304 8 m 1 8 F per 1 000 ft up to 3048 m 10 000 ft applies No direct sunlight is allowed The maximum permissible rate of change is 10 C hr 18 F hr The type and number of options installed may reduce the upper temperature and humidity limits Operating with a fan fault or above 30 C 86 F may reduce system performance Storage maximum humidity of 95 is based on a maximum temperature of 45...

Страница 76: ...r ESD electrostatic discharge IML Integrated Management Log KVM keyboard video and mouse LOM LAN on Motherboard LRDIMM load reduced dual in line memory module NVRAM nonvolatile memory PCIe Peripheral Component Interconnect Express POST Power On Self Test PSP HP ProLiant Support Pack RBSU ROM Based Setup Utility ...

Страница 77: ...istered dual in line memory module SAS serial attached SCSI SATA serial ATA SD Secure Digital SIM Systems Insight Manager SUV serial USB video TPM Trusted Platform Module UDIMM unregistered dual in line memory module USB universal serial bus ...

Страница 78: ...oviding documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback ...

Страница 79: ...M installation guidelines 68 DIMM slot locations 68 documentation 78 documentation feedback 78 drive bays 63 drive cabling 70 drive LEDs 65 drives 65 drives determining status of 65 E electrostatic discharge 22 environmental specifications 75 error messages 55 external cables 72 external USB functionality 61 F features 63 firmware upgrade utility troubleshooting 55 front panel components 63 G grou...

Страница 80: ...ty considerations 22 safety information 22 23 SAS cabling 72 SAS drives 15 65 serial label pull tab 63 64 serial number 59 server blade components 63 server blade release button 63 server blade release lever 63 server blade removal 24 server blade specifications 75 server specifications 75 specifications 75 specifications environmental 75 specifications server blade 75 static electricity 22 suppor...