Removal and replacement procedures 44
3.
Align and install the heatsink. Alternate tightening the screws until the heatsink is seated properly.
4.
Install the DIMM baffle and connect the drive cable to the SAS controller ("
" on page
5.
Install the front panel/drive cage assembly ("
Front panel/drive cage assembly
" on page
6.
Install all drives ("
" on page
7.
Install the access panel ("
" on page
Processor
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To avoid damage to the system board:
•
Do not touch the processor socket contacts.
•
Always install the processor socket cover after removing the processor from the socket.
•
Do not tilt or slide the processor when lowering the processor into the socket.
CAUTION:
To avoid damage to the processor:
•
Handle the processor only by the edges.
•
Do not touch the bottom of the processor, especially the contact area.
CAUTION:
To prevent possible server blade overheating, always populate each processor
socket with a processor socket cover and a heatsink blank or a processor and a heatsink.
CAUTION:
To prevent possible server blade malfunction and damage to the equipment,
multiprocessor configurations must contain processors with the same part number.
CAUTION:
The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
IMPORTANT:
Processor socket 1 must always be populated. If processor socket 1 is empty, the
server blade does not power up.