Hardware options installation 38
4.
Remove the access panel (on page
5.
Do one of the following:
o
Remove the storage controller/NVMe pass-through board (on page
o
Remove the direct connect SATA cable (on page
6.
Remove all DIMM baffles ("
7.
Remove the front panel/drive cage assembly (on page
8.
Install the M.2 SSD enablement board:
a.
Insert the M.2 SSD enablement board into the system board connector.
b.
Secure the M.2 SSD enablement board by tightening the screw.
9.
Install the front panel/drive cage assembly (on page
10.
Install all DIMM baffles ("
11.
Do one of the following:
o
Install the storage controller/NVMe pass-through board.
o
Install the direct connect SATA cable (on page
12.
Install the access panel (on page
13.
Install the server blade (on page
14.
Power up the server blade (on page
Installing a processor
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent possible server blade malfunction and damage to the equipment,
multiprocessor configurations must contain processors with the same part number.
CAUTION:
The heatsink thermal interface media is not reusable and must be replaced if the
heatsink is removed from the processor after it has been installed.
Содержание ProLiant BL460c Gen9
Страница 82: ...Support and other resources 82 ...
Страница 83: ...Support and other resources 83 ...