Removal and Replacement Procedures
2-18
HP ProLiant BL20p Generation 3 Server Blade Maintenance and Service Guide
4.
Press the fan retention tab (1) and lift up the assembly (2).
Figure 2-16: Removing a fan assembly
To replace the component, reverse the removal procedure. If the air baffle becomes loose,
reverse the procedure in step 6 of “SCSI Backplane” in this chapter to reinstall the air baffle.
HP ProLiant BL30p Dual Port Fibre Channel Adapter
An optional ProLiant BL30p Dual Port Fibre Channel (FC) adapter enables FC support (for
clustering capabilities) and SAN connection when used in conjunction with the RJ-45 Patch
Panel 2 or the GbE2 Interconnect Switch with FC pass-through option. The card is installed
on top of the standard NIC mezzanine card. Refer to the
HP ProLiant BL20P Generation 3
Server Blade Setup and Installation Guide
for more information about connecting to a SAN.
To remove the FC adapter:
1.
Power down the server blade and remove it from the server blade enclosure. Refer to the
“Server Blade Preparation” section in this chapter.
2.
Remove the access panel. Refer to the “Access Panel” section in this chapter.