Switch Memory and Configuration
Using Primary and Secondary Flash Image Options
Using Primary and Secondary Flash
Image Options
The switch features two flash memory locations for storing switch software
image files:
■
Primary Flash:
The default storage for a switch software image.
■
Secondary Flash:
The additional storage for either a redundant or an
alternate switch software image.
With the Primary/Secondary flash option you can test a new image in your
system without having to replace a previously existing image. You can also
use the image options for troubleshooting. For example, you can copy a
problem image into Secondary flash for later analysis and place another,
proven image in Primary flash to run your system. The switch can use only
one image at a time.
The following tasks involve primary/secondary flash options:
■
Displaying the current flash image data and determining which switch
software versions are available
■
Switch software downloads
■
Replacing and removing (erasing) a local switch software version
■
System booting
Displaying the Current Flash Image Data
Use the commands in this section to:
■
Determine whether there are flash images in both primary and secondary
flash
■
Determine whether the images in primary and secondary flash are the
same
■
Identify which switch software version is currently running
Viewing the Currently Active Flash Image Version.
This command
identifies the software version on which the switch is currently running, and
whether the active version was booted from the primary or secondary flash
image.
Syntax
:
show version
6-12
Содержание ProCurve Series 2810
Страница 1: ...Management and Configuration Guide 2810 www procurve com ProCurve Series 2810 Switches N 10 XX ...
Страница 2: ......
Страница 3: ...ProCurve Series 2810 Switches July 2006 Management and Configuration Guide ...
Страница 56: ...Using the Menu Interface Where To Go From Here This page is intentionally unused 3 16 ...
Страница 98: ...Using the Web Browser Interface Status Reporting Features This page is intentionally unused 5 26 ...
Страница 240: ...Port Trunking Port Status and Configuration This page is intentionally unused 11 26 ...
Страница 320: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation This page is intentionally unused A 24 ...
Страница 350: ...Monitoring and Analyzing Switch Operation Locating a Device This page is intentionally unused B 30 ...
Страница 404: ...MAC Address Management Viewing the MAC Addresses of Connected Devices This page is intentionally blank D 8 ...
Страница 408: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time This page is intentionally unused E 4 ...
Страница 419: ... This page is intentionally unused ...