SROS Command Line Interface Reference Guide
G.703 Interface Configuration Command set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
683
test-pattern [ones | zeros]
Use the
test-pattern
command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the
no
form of this command to cease pattern generation.
Syntax Description
ones
Generates a test pattern of continous ones.
zeros
Generates a test pattern of continous zeros.
Default Values
No defaults necessary for this command.
Usage Examples
The following example activates the pattern generator for a stream of continuous ones:
ProCurve(config)#
interface e1 1/2
ProCurve(config-e1 1/2)#
test-pattern ones