SROS Command Line Interface Reference Guide
DSX-1 Interface Configuration Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
592
coding [ami | b8zs]
Use the
coding
command to configure the line coding for a DSX-1 physical interface. This setting must
match the line coding supplied on the circuit by the external device.
Syntax Description
ami
Configures the line coding for alternate mark inversion (AMI).
b8zs
Configures the line coding for bipolar eight zero substitution (B8ZS).
Default Values
By default, all DSX-1 interfaces are configured with B8ZS line coding.
Functional Notes
The line coding configured in the unit must match the line coding of the DSX-1 circuit. A mismatch will
result in line errors (e.g., BPVs).
Usage Examples
The following example configures the DSX-1 interface for AMI line coding:
ProCurve(config)#
interface t1 1/2
ProCurve(config-t1 1/2)#
coding ami