background image

61195872L1-13C, August 2005

www.procurve.com

Copyright 2005 Hewlett-Packard Development Company, LP

Quick Start Guide

5991-2104

ProCurve Secure Router dl 2xT1 Module

J8453A

S

PECIFICATIONS

Operating 
Modes

T1/FT1 Frame Relay, T1/FT1 PPP, T1/FT1 Multilink PPP,
T1/FT1 Multilink Frame Relay, T1/FT1 HDLC

T1/FT1 
Interface

Supported Standards: AT&T TR 62411, AT&T TR 54016, 
Bellcore TR 194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB
Connector: RJ-48C
DS0 Assignment: Programmable

Clock Source

Network, internal, and through

Diagnostics

Test pattern Generation and Detection: QRSS, 511,
2

15

 - 1, 2

20

 - 1, all ones, all zeros

Network loopbacks (local and remote); responds to both 
inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data (15 minutes 
and 24 hours)

Compliance

FCC Part 15 Class A, EN 55022 Class A, EN 55024, 
EN 61000-3-2, EN 61000-3-3
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950, IEC 60950

Physical

Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at 
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent, 
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)

I

NSTALLATION

 I

NSTRUCTIONS

1.

Remove power from the unit.

2.

Slide the ProCurve Secure Router dl 2xT1 Module into the option slot 
until the module is firmly seated against the chassis.

3.

Secure the screws at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete the installation of the base unit.

6.

Restore power to the unit.

Note

For safety information for the routers and all modules, 
please refer to the safety and ESD precautions in the 

ProCurve Secure Router Installation Guide

 included in 

your router shipment.

T1/1 

AND

 T1/2 N

ETWORK

 (RJ-48C) C

ONNECTION

 P

INOUT

Pin

Name

Description

1

R1

Receive data from the network - Ring 1

2

T1

Receive data from the network - Tip 1

3

Unused

4

R

Transmit data toward the network - Ring

5

T

Transmit data toward the network - Tip

6-8

Unused

Note

An optional backup module is required for backup 
applications.
For a description of the backup connection pinouts, refer 
to the Quick Start Guide included with your backup 
module

Отзывы: