clock source [line* | internal]

Configures the source of the clock for the system.

line

*

Recovers clock from the T1 circuit.

internal

Provides clocking using the internal oscillator.

coding [ami | b8zs*]

Configures the line coding for the T1 interface.

ami

Signifies Alternate Mark Inversion.

b8zs

*

Signifies Bipolar Eight Zero Substitution.

fdl [ansi* | att | none]

Configures the format of the facility data link on the T1.

ansi

*

Configures the FDL for ANSI T1.403 standard.

att

Configures the FDL for ATT TR54016 standard.

none

No FDL standard configured.

framing [d4 | esf*]

Configures the framing format of the T1 interface.

d4

Specifies Superframe T1 framing.

esf

*

Specifies Extended Superframe T1 framing.

lbo long [0

*

 | -7.5 | -15 | -22.5]

Sets the line build out (in dB) for the T1 Interface. Use the 

lbo long

 command 

for T1 interfaces with a cable length greater than 655 feet.

lbo short [0 – 655 ft]

Sets the line build out (in feet) for the T1 Interface. Use the 

lbo short

 command 

for T1 interfaces with a cable length less than 655 feet.

loopback network [line | payload]

Initiates a loopback on the interface towards the network. Deactivate using the 

no loopback network

 command.

line

Initiates a metallic loopback of the physical T1 network 
interface.

payload

Initiates a loopback of the T1 framer (CSU portion) of 
the T1 network interface.

loopback remote line [fdl | inband]

Sends a loopback code to the remote unit to initiate a line loopback. Deactivate 
using the 

no loopback remote line

 command.

fdl

Uses the facility data link (FDL) to initiate a full 1.544 
Mbps physical (metallic) loopback of the signal received 
by the remote unit from the network.

inband

Uses the inband channel to initiate a full 1.544 Mbps 
physical (metallic) loopback of the signal received by 
the remote unit from the network.

loopback remote payload

Sends a loopback code to the remote unit to initiate a payload loopback. 
Deactivate using the 

no loopback remote payload

 command.

remote-alarm rai

Enables transmission of RAI in response to a loss of frame. Use the 

no

 form of 

this command to disable.

remote-loopback

Configures the unit to respond to loopbacks initiated by a remote unit (or service 
provider). The 

no

 version of this command configures the interface to ignore T1 

loop commands

show test-pattern

Displays the current pattern error count.

shutdown

Turns off the interface. By default, all interfaces are disabled. Use the 

no 

shutdown

 command to enable the interface and allow it to pass data.

snmp trap link-status

Enables the interface to send SNMP traps when there is an interface status 
change and controls the SNMP variable, 

ifLinkUpDownTrapEnable

.

tdm-group

 

<group#> timeslot

 

<DS0 range> speed [56 | 64*]

Creates a group of contiguous DS0s on this interface to be used
during the 

bind

 process.

<

group#

>

Number label (1 to 1024) to identify this TDM group.

<

DS0 range

>

DS0s in this group in the form: 

<starting DS0 - ending DS0>

56 | 64*

(Optional) 

Specifies a DS0 rate of 56 kbps or 64 kbps. 

test-pattern [clear | insert | ones | p511 | qrss | zeros]

Initiates test pattern generation from the unit.

clear

Clears the test pattern error count.

insert

Inserts an error into currently active test pattern.

ones

Generates a pattern of continuous ones.

p511

Generates a repeating pattern of ones and zeros.

qrss

Generates a random pattern of ones and zeros.

zeros

Generates a pattern of continuous zeros.

* Indicates default values.