![HP photosmart 850 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/hp/photosmart-850/photosmart-850_command-reference-manual_159429017.webp)
12
Parameters
auto
: Sets the interface to operate in autonegotiation mode.
full
: Sets the interface to operate in full duplex mode.
Usage guidelines
Support for this command varies with device models. For more information, see
About the Command
References for HP Unified Wired-WLAN Products
.
Examples
# Configure interface Ten-GigabitEthernet 1/0/1 to operate in autonegotiation mode.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] duplex auto
flow-interval
Use
flow-interval
to set the interface statistics polling interval.
Use
undo flow-interval
to restore the default interval.
Syntax
flow-interval
interval
undo flow-interval
Default
The interface statistics polling interval is 300 seconds.
Views
Layer 2 Ethernet interface view
Default command level
2: System level
Parameters
interval
: Sets the statistics polling interval, in seconds. It is in the range of 5 to 300 and must be a multiple
of 5.
Examples
# Set the statistics polling interval to 100 seconds on Ten-GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] flow-interval 100
interface
Use
interface
to enter interface view.
Syntax
interface
interface-type
interface-number