Installing Hardware Options
HP ProLiant ML530 Generation 2 Server Setup and Installation Guide
3-11
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: d-ch3 Installing Hardware Options.doc
Codename: Seattle Slew Part Number: 225579-002 Last Saved On: 1/8/03 3:00 PM
2.
For rack-model servers already installed in a rack, complete the following steps
to prepare the server for the removal of the access panel:
a.
Loosen the front panel thumbscrews to release the server from the rack.
b.
Pull the server out from the front of the rack until it stops.
3.
Loosen the screws located on the front panel of the server to release the access
panel (1).
IMPORTANT:
One screw is keyed for a Torx T-15 tool only. Use the Torx T-15 tool that
ships with the server to remove this screw. See “Locating and Removing the Torx T-15
Tool” in this chapter. The other two fasteners are thumbscrews and are loosened by hand.
4.
Slide the access panel 1.27 cm (0.5 inch) toward the rear of the unit (2).
5.
Lift and remove the access panel.
Figure 3-6: Removing the access panel (tower server)
6.
Turn the access panel over to locate the hood labels. These labels provide
information about installing and configuring drives, installing memory, and
installing additional processors.
7.
Set the panel aside and use the label to locate components inside the chassis.
8.
Reverse steps 1-5 to reinstall the access panel.