Removal and replacement procedures 51
11.
Disconnect all cables connected to the system board.
12.
Loosen the two system board thumbscrews.
13.
Using the system board tray handles, slide the tray forward and remove the system board.
To replace the component, reverse the removal procedure.
NOTE:
Install the processor socket cover onto the processor socket of the failed system board. The cover
protects the socket during shipping when the failed board is returned.
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
During the server startup sequence, press the
F9
key to access RBSU.
2.
Select the
System Options
menu.
3.
Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
4.
Press the
Enter
key to clear the warning.
5.
Enter the serial number and press the
Enter
key.
6.
Select
Product ID
.
7.
Enter the product ID and press the
Enter
key.
8.
Press the
Esc
key to close the menu.
9.
Press the
Esc
key to exit RBSU.
Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.
Power supply backplane
To remove the component:
1.
Power down the server (on page
2.
Do one of the following:
Содержание ML350 - ProLiant - G2