Intercode Delay
Specifies the delay between labels transmitted to the host for this interface. The
selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 =
00, 5 = 05, 20 = 20, etc
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
, that
represent the duration which was determined in the steps above. You will
hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set
this feature.
Table 12. Wedge Intercode Delay Examples
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
No Delay
5 Seconds
60 Seconds
99 Seconds
2
Pad with leading zero(es)
00
05
60
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
5
Scan Two Characters From
‘0’ and ‘0’
‘0’ and ‘5’
‘6’ and ‘0’
‘9’ AND ‘9’
7
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Linear Barcode Scanner II
Страница 1: ...HP Linear Barcode Scanner II Programming Reference Guide ...
Страница 10: ...viii Programming Reference Guide ...
Страница 240: ...Symbologies 230 Programming Reference Guide NOTES ...
Страница 288: ...278 Programming Reference Guide Code 32 Codabar Code 93 Code 11 ...
Страница 290: ...280 Programming Reference Guide NOTES ...
Страница 292: ...282 Programming Reference Guide 6 7 8 9 ...
Страница 293: ...Programming Reference Guide 283 A B C D E F ...
Страница 294: ...284 Programming Reference Guide NOTES ...
Страница 306: ......