background image

Pedestal Kit Installation Guide for HP
Integrity rx2800 i2 and HP Proliant DL380
G6 & DL385 G6 Servers

HP Part Number: AM251-9000A
Published: January 2010
Edition: 1

Содержание Integrity rx2800 - i2

Страница 1: ...Pedestal Kit Installation Guide for HP Integrity rx2800 i2 and HP Proliant DL380 G6 DL385 G6 Servers HP Part Number AM251 9000A Published January 2010 Edition 1 ...

Страница 2: ...hange without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein ...

Страница 3: ...s from the server 9 Attach the pedestal kit top and bottom 10 Attach the bezel cover 12 Attach the pedestal kit side pieces 13 Attach the pedestal feet 15 3 Accessing internal components 17 4 Removing the server from the pedestal kit 21 Required tools 21 Power off the server and remove cables 21 Removing the pedestal kit 21 5 Support and other resources 25 Publishing history 25 Related information...

Страница 4: ... kit side piece 13 2 6 Thumb screw locations 14 2 7 Attaching the feet 15 3 1 Removing the pedestal kit feet 17 3 2 Thumbscrew locations 18 3 3 Removing the side piece 18 3 4 Access panel removal 19 4 1 Removing the pedestal kit feet 21 4 2 Thumbscrew locations 22 4 3 Removing the side piece 22 4 4 Removing the bezel cover 23 4 5 Removing the pedestal top piece 23 4 List of Figures ...

Страница 5: ...ive changes are made Document updates may be issued between editions to correct errors or document product changes To ensure that you receive the updated or new editions subscribe to the appropriate product support service See your HP sales representative for details The latest version of this document can be found online at http www hp com go Integrity_Servers docs and http www hp com go Proliant...

Страница 6: ...6 ...

Страница 7: ... including but not limited to raised floor tiles worn air conditioning parts heating ducts rotor brushes in vacuum cleaners or printer component wear Because metallic particulates conduct electricity they have an increased potential for creating short circuits in electronic equipment This problem is exaggerated by the increasingly dense circuitry of electronic equipment Over time very fine whisker...

Страница 8: ...8 ...

Страница 9: ...need to remove the rails before mounting it in the pedestal kit To remove the component 1 Slightly pull the rail lock away from the rail to unlock the rail See Figure 2 1 page 9 2 Slide the rail toward the front of the server to disengage the rail from the posts on the server 3 Repeat these steps for the rail on the other side of the server Figure 2 1 Removing the rails from the server Required to...

Страница 10: ...t side See Figure 2 2 page 10 for the server and pedestal orientations Figure 2 2 Front of server 3 Server bottom pedestal left 1 Server top pedestal right 2 4 Server left pedestal top Server right pedestal bottom The pedestal kit bottom attaches to the right side of the server when the server is in the horizontal position The pedestal kit top attaches to the left side of the server when in the se...

Страница 11: ...destal component flush against the server 3 Slide the pedestal component forward until it locks into place Figure 2 3 Installing the pedestal bottom piece 4 Stand the server up on the bottom piece of the pedestal kit that was just installed so the server is in the vertical position CAUTION The server is heavy Be careful when lifting it to the vertical position Without the feet installed the server...

Страница 12: ... to the front of the server starting from the bottom of the pedestal kit 2 Push the bezel cover into place against the pedestal kit top piece until the tabs on the bezel cover snap into place Figure 2 4 Attaching the bezel Cover 12 Installing the server into the pedestal kit ...

Страница 13: ...he ventilation holes in the pedestal kit right side piece must be matched up with the ventilation holes on the top cover of the HP Integrity rx2800 i2 server to allow for proper cooling and air flow Failure to heed this warning will cause the server to shut down with an overtemp condition To attach the component 1 Align the posts on the pedestal kit right side piece with the slots in the pedestal ...

Страница 14: ... pedestal side by hand tightening the captive thumb screws on the rear of the server Figure 2 6 Thumb screw locations Repeat these steps to install the left side piece 14 Installing the server into the pedestal kit ...

Страница 15: ... pedestal feet slide into the slots on the pedestal bottom two on each side The feet are all the same and can be mounted in any slot on the bottom piece of the pedestal kit Figure 2 7 Attaching the feet Attach the pedestal feet 15 ...

Страница 16: ...16 ...

Страница 17: ...ables 2 Remove the pedestal kit feet Figure 3 1 Removing the pedestal kit feet 3 Lay the server on the left side facing the front of the server The right side of the pedestal kit with the ventilation holes should be facing up 4 Unscrew the captive thumbscrews on the rear of the pedestal kit for the right side pedestal kit piece 17 ...

Страница 18: ...umbscrew locations 5 Slide the right side pedestal kit piece toward the back of the server and lift up on the piece to remove it from the pedestal Figure 3 3 Removing the side piece 18 Accessing internal components ...

Страница 19: ...put the pedestal kit back on the server 1 Close the access panel 2 Install the right side pedestal piece 3 Tighten the thumbscrews on the rear of the server 4 Stand the server up onto the bottom piece of the pedestal kit 5 Install the pedestal kit feet into the slots on the bottom of the pedestal kit 6 Connect the cables and restart the server 19 ...

Страница 20: ...20 ...

Страница 21: ...structions provided in the server service guide 2 Disconnect the power and LAN cables connected to the server Removing the pedestal kit 1 Remove pedestal feet Figure 4 1 Removing the pedestal kit feet 2 Remove the pedestal side pieces by unscrewing the captive thumbscrews on the rear of the pedestal kit and sliding the side pedestal kit pieces toward the back of the server Required tools 21 ...

Страница 22: ...gure 4 2 Thumbscrew locations Figure 4 3 Removing the side piece 3 Release the locking tabs behind the top corners of the bezel cover and remove the component 22 Removing the server from the pedestal kit ...

Страница 23: ...nlock the pedestal top piece from the server See Figure 4 5 for the pedestal top and bottom piece lock release locations Figure 4 5 Removing the pedestal top piece c Slide the pedestal top piece toward the back of the server to release it from the server d Once the pedestal component has moved about 1 4 inch the lock releases and you can release the tab e Pull the pedestal kit top piece away from ...

Страница 24: ...24 ...

Страница 25: ... uses the following typographical conventions Title The title of a document or a CD Emphasis Text that is emphasized Bold Text that is strongly emphasized WARNING A warning calls attention to important information that if not understood or followed will result in personal injury or nonrecoverable system problems CAUTION A caution calls attention to important information that if not understood or f...

Страница 26: ...26 ...

Страница 27: ...val 17 21 pedestal side removal 18 pedestal sides attaching 13 pedestal top attaching 10 removal 23 R rack rail removal 9 required tools disassembly 21 S server orientation 10 powering down 21 side piece removal 22 static electricity see electricity static T thumbscrew locations 18 22 tools required instalation 9 W warnings electrical 7 metallic particulate contamination 7 static electricity 7 Z z...

Страница 28: ... AM251 9000A Printed in the US ...

Отзывы: