1 HPE Integrity NonStop X NS7 Systems
The HPE Integrity NonStop X NS7 system family introduces Intel® Xeon® x86 technology to
NonStop by using a new high bandwidth, low latency InfiniBand system interconnect that is
fully-integrated with the fault-tolerant HPE NonStop Operating system.
The L15.08 RVU introduced the NS7 X1.
The L16.05 RVU introduces the
and the
.
Table 1 Characteristics of the NS7 X1
Intel® Xeon® x86 processors
Processor/Processor model
L15.02 and later RVUs
Supported RVU for the system
The core license file is required. See
2-, 4-, and 6-core software
licensing options
See the
CLuster I/O Module (CLIM) Software Compatibility Guide
for supported
version
CLIM DVD (Minimum DVD
version required for RVU)
NOTE:
This file is preinstalled on new systems
36U or 42U
Rack
2 to 16 processors configured in pairs
Processors
64GB, 128GB, and 192GB memory configurations
Memory
See
Planning Kernel Managed Swap (KMS) Space (page 59)
Kernel Managed Swap Facility
56 CLuster I/O Modules (CLIMs) — Storage, IP, or Telco
Maximum CLIMs in a 16 CPU
NonStop X system
Minimum CLIMs for
fault-tolerance
•
2 Storage CLIMs
•
2 Networking CLIMs (IP or Telco)
A Storage CLIM pair supports a maximum of 4 SAS disk enclosures
Maximum SAS disk enclosures
100 per Storage CLIM pair.
Maximum SAS disk drives
HPE LTO6 Tape Data Cartridge, HPE NonStop BackBox VTC, and HPE NonStop
BackBox VTR
Tape support through Storage
CLIMs
0 to 4 (2 pairs)
Minimum/maximum IO
Expansion IB Switches
HPE XP 7 Storage Array and HPE XP P9500 Storage Array
ESS support through Storage
CLIMs
This file is required; see
Core licensing file
Redundant configuration only
Maintenance LAN
2
Minimum NonStop System
Consoles for fault-tolerance
Supported. For more information, see the
NonStop X Cluster Solution Manual
Connection to NonStop X
Cluster Solution
“NonStop X NS7 Standard and Optional Hardware” (page 10)
describes the NS7 system hardware.
Because NS7 systems offer flexibility in how hardware is distributed in the rack, configurations
can vary.
shows two example configurations for AC power NS7 systems.
7
Содержание Integrity NonStop X NS7
Страница 8: ...Figure 1 Example NS7 System Configurations 42U and 36U 8 HPE Integrity NonStop X NS7 Systems ...
Страница 39: ...Figure 14 Example of Bottom AC Power Feed in a Rack Without UPS AC Power Feeds in the Rack 39 ...
Страница 40: ...Figure 15 Example of Top AC Power Feed in a Rack Without UPS 40 NS7 System Installation Specifications ...
Страница 41: ...Figure 16 Example of Top AC Power Feed in a Rack With Single Phase UPS AC Power Feeds in the Rack 41 ...
Страница 43: ...Figure 18 Example of Top AC Power Feed in a Rack With Three Phase UPS AC Power Feeds in the Rack 43 ...
Страница 62: ...62 HPE Integrity NonStop X NS7 CG X2 System ...