Site preparation
The BL860c i4 does not have cooling or power systems. Cooling and power is provided by the c-Class
enclosure.
IMPORTANT:
To avoid hardware damage, allow the thermal mass of the product to equalize to the temperature
and humidity of the installation facility after removing the shipping materials. A minimum of one hour
per 10°C (50°F) of temperature difference between the shipping facility and installation facility is
required.
Server blade dimensions and weight
Table 1: Server blade dimensions and weight for the BL860c i4
Dimensions
value
Height
36.63 cm (14.42 in.)
Width
5.14 cm (2.025 in.)
Depth
48.51 cm (19.1 in.)
Weight
Unloaded: 8.6 kg (19 lb)
Fully loaded: 11.3 kg (25 lb)
Table 2: Blade Link dimensions and weight
Blade Link type
Height
Width
Weight
BL1 (BL860 i4)
44 mm (1.73 in)
51 mm (2 in)
.5 lb (.22 kg)
BL2 (BL870 i4)
44 mm (1.73 in)
106 mm (4.17 in)
1 lb (.45 kg)
BL4 (BL890 i4)
44 mm (1.73 in)
212 mm (8.34 in)
2 lb (.90 kg)
Enclosure information
All three blade configurations are supported in HPE c7000 and c3000 Enclosures.
For more enclosure information see:
•
http://www.hpe.com/support/Bladesystem_c3000_Enclosures_Manuals
•
http://www.hpe.com/support/Bladesystem_c7000_Enclosures_Manuals