Figure 82 Press junction box connections closeup
•1. Open the junction box on the rear Output wall.
•2. Remove the Printing engine CC521 cable that consists of 9 wires
connections in the junction box.
•3. Replace the CC521 cable with the new CC250
cable.
a. Connect the brown wire to the bottom (positive) row in slot 15.
b. Connect the black wire to the bottom (positive) row in slot 3.
c. Connect the green wire to the bottom (positive) row in slot 16.
d. Connect the red wire to the middle (negative) row in slot 15.
e. Connect the blue wire to the middle (negative) row in slot 16.
f.
Connect the yellow wire to the middle (negative) row in slot 3.
g. Connect the gray wire to the top (numbered) row in slot 3.